Custom app/plugin, Overview field description – Perle Systems IOLAN SCS User Manual

Page 297

Advertising
background image

297

Management

Custom App/Plugin

Overview

You can create custom applications for the IOLAN by using the Perle SDK. See the SDK
Programmer’s Guide
(the SDK and guide are found on the Perle website at

www.perle.com/downloads/index.shtml

) for information about the functions that are

supported. You must download the program and any ancillary files to the IOLAN and set the

Serial

Port Profile

to

Custom App/Plugin

to run a custom application. You must also specify the program

executable in the

Command Line

parameter.

A custom application or plugin can be run on the serial port. In this situation, the application will start
once the serial port is activated and operate solely on the context of that serial port and any network
communications related to that serial port. You could run a different custom application on each serial
port. The serial port custom application or plugin is configured by specifying the

Custom

App/Plugin

profile for the serial port.

The system level custom application or plugin will begin execution immediately following the system
startup. It runs on the context of the whole system and can access network communications as well as
any or all serial ports.

Field Description

Configure the following parameter:

Recurring Start
Date

Sets the relative date and time in which the IOLAN’s clock will change to
summer time (daylight saving time) hours. Sunday is considered the first day of
the week.

Recurring End Date Sets the relative date and time in which the IOLAN’s clock will end summer

time hours and change to standard time. Sunday is considered the first day of
the week.

Command Line

The name of the application that has been already been downloaded to the
IOLAN, plus any parameters you want to pass to the program. For example,
using sample

outraw

program (this is sample program supplied with the

SDK), you would type:

outraw -s 0 192.168.2.1:10001 Acct:10001

if you were starting the application on the Server (notice the

-s 0

parameter

specifies serial port 1 to this particular application).

Field Format: Maximum of 80 characters

Advertising