97

FX-301

The threshold value is displayed.

‘ ’ blinks in the digital display.

The incident light intensity appears in the digital
display and the setting is complete.

6

5

7

8

If jog switch is turned to the ‘

ם

’ side, ‘ ’ scrolls

(twice) the display from right to left, and the threshold
level is shifted to a value approx. 15 %
higher (lower sensitivity) than that set
at 2. (Note 1)
This is used in case of reflective type fibers.
If jog switch is turned to the ‘

מ

’ side, ‘ ’ scrolls

(twice) the display from left to right, and the threshold
level is shifted to a value approx. 15 %
lower (higher sensitivity) than that set
at 2. (Note 1)
This is used in case of thru-beam type
fibers.

The threshold value is displayed.

‘ ’ blinks in the digital display.

The incident light intensity appears in the digital
display and the setting is complete.

Note: Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable.

4

5

6

7

Teaching
• The threshold values can be set by 2-level teaching, limit teaching or full-

auto teaching, when the MODE indicator / TEACH (yellow) lights up.

• This is the method of setting the threshold value by teaching two levels, corresponding to

the object present and object absent conditions. Normally, setting is done by this method.

In case of 2-level teaching

• This is the method of setting the threshold value by teaching

only the object absent condition (stable incident light
condition). This is used for detection in the presence of a
background body or for detection of small objects.

In case of limit teaching

If the teaching is accepted, the read incident light intensity
blinks in the digital display and the threshold value is set
at the mid-value between the incident light intensities in
the object present and the object absent conditions. After
this, the judgment on the stability of sensing is displayed.

• In case stable sensing is possible: ‘ ’ is displayed.

Stability indicator (green) blinks.

• In case stable sensing is not possible: ‘ ’ blinks.

Stability indicator (green) is off.

The threshold value is displayed.

‘ ’ blinks in the digital display.

The incident light intensity appears in the digital
display and the setting is complete.

If the teaching is accepted, the read incident light intensity
blinks in the digital display and the threshold value is set
at the mid-value between the incident light intensities in
the object present and the object absent conditions. After
this, the judgment on the stability of sensing is displayed.

• In case stable sensing is possible: ‘ ’ is displayed.

Stability indicator (green) blinks.

• In case stable sensing is not possible: ‘ ’ blinks.

Stability indicator (green) is off.

After this, the judgment on whether the setting shift
amount can be shifted or not is displayed.

• In case shifting is possible: ‘ ’ blinks.

• In case shifting is not possible: ‘ ’ blinks.

5

6

7

Set the fiber within the sensing
range.
Press MODE key to light up
MODE indicator / TEACH
(yellow).

Press jog switch in the object present condition.
If the teaching is accepted, the read incident light intensity blinks in the digital display.

1

2

Step

Description

Display

Thru-beam type

Reflective type

MODE indicator / TEACH (yellow) blinks.
Press jog switch in the object absent condition.

3

Thru-beam type

Reflective type

Set the fiber within the sensing
range.
Press MODE key to light up
MODE indicator / TEACH
(yellow).

Press jog switch in the object absent condition.
If the teaching is accepted, the read incident light
intensity blinks in the display.

MODE indicator / TEACH (yellow) blinks.
Turn jog switch to the ‘

ם

’ side or ‘

מ

’ side.

1

2

3

4

Step

Description

Display

Set the fiber within the sensing
range.
Press MODE key to light up
MODE indicator / TEACH
(yellow).

Press the jog switch continuously for 0.5 sec. or more
with the object moving on the assembly line. (The
incident light intensity is displayed during sampling.)

‘ ’ is displayed on the digital display. Release the
jog switch when the object has passed.

1

2

3

Step

Description

Display

4

Notes: 1) The threshold value’s shift amount can be selected in PRO mode.

Refer to the ‘SUNX fiber sensor home page’ (http://www.fiber-
sensor.com) for more details pertaining to setting instructions.
(Increments of 5 % between –45 and 45 % for setting possible. 0 %
default.)

Notes:

2) Do not move or bend the fiber cable after the sensitivity setting.

Detection may become unstable.

Notes: 1) The approx. 15% amount of shift is the initial value. The amount of

shift can be changed in the PRO mode from approx. 5 to 80 %
(5 % step). Refer to the ‘Fiber Sensor Guide Book’ or ‘SUNX fiber
sensor home page’ (http://www.fiber-sensor.com) for more details
pertaining to setting instructions.

Notes:

2) Do not move or bend the fiber cable after the sensitivity setting.

Detection may become unstable.

PRECAUTIONS FOR PROPER USE

Amplifier

• Full auto-teaching is used when it is desired to set the threshold value

without stopping the assembly line, with the object in the moving condition.

In case of full auto-teaching

FX-301B(P)/G(P)/H(P) only

Thru-beam type

Reflective type

08/2005