• Protect the amplifier from heat radiation or hot air.
• With the 350 ЊC

662 °F

heat-resistant type fiber, the

surface of the fiber head or the spiral may be discolored

by heat. However, this does not affect its performance.

102

FX-301

Connection with reflective coaxial type fiber
• With reflective coaxial type fiber, insert the center fiber

cable (single-core) into the beam-emitting inlet and the
outer fiber cable (multi-core) into the beam-receiving inlet.

FD-H35-M2 or FD-H20-M1 is marked ‘P’ on the beam-
emitting fiber cable and ‘D’ on the beam-receiving fiber cable.

FD-WG4, FD-WSG4 and FD-G4, FD-G6, FD-G6X are
composed of beam-emitting and beam-receiving fiber
cables that are different in diameter.

FD-G500, FD-EG1, FD-EG2, FD-EG3, FD-E22,
FD-H20-21 and FD-ENM1S1 are marked P on the
beam-emitting fiber cable.

Fiber cable bending radius
• If the fiber cable is bent at a smaller bending radius than allowable

bending radius, the sensing range decreases due to beam attenuation.

Fiber

Note: Please note that the 350 °C

662 °F

heat-resistant fibers, vacuum-
resistant and chemical-resistant
fibers cannot bend less than the
allowable bending radius.

Notes: 1) In case the fiber cables are not inserted to a position where they

stop, the sensing range reduces.

Notes:

2) Before connecting fiber cables to the amplifier, mount the fiber

attachments on their ends.

PRECAUTIONS FOR PROPER USE

.

•

Take care that, since the aperture angle of this product is very

narrow, the beam may not be received depending upon the setting.
At the time of installation, determine a reference plane, as shown in
the figure below, and taking sufficient care against beam
misalignment or tilt, install the emitting and receiving fibers so that
they are parallel.

<

FT-K8

>

Narrow beam type fiber mounting

•

Install the fiber using M3
countersunk head screws.
The tightening torque should
be 0.3 N

⅐m or less.

Further, when using the fiber
at places having intense
vibrations, use a screw-
locking adhesive, etc.

•

If mineral oil or solvent containing mineral oil component
adheres to the sensing surface, the lens may be
deformed. Take sufficient care to handle them.

•

Take care that, since the aperture angle of this product is

very narrow, the beam may not be received depending
upon the setting.
At the time of installation, determine a reference plane, as
shown in the figure below, and taking sufficient care
against beam misalignment or tilt, install the beam-
emitting and receiving fibers so that they are parallel.

Thru-beam type wide beam fiber mounting

<

FT-KV8 / FT-WKV8

>

How to bend sleeve

•

The bending radius must be R10 mm

R0.394 in

or more.

Please bend gradually using the fiber bender (FB-1) or a
round bar of "20 mm

"

0.787 in

or more.

Note: Do not bend the sleeve of side-view type, narrow beam type, narrow-

view type and ultra-small diameter type fiber.

Method of fixing fiber cable

•

If fixing the fiber cable in position, make sure that it is set in
a manner as shown below, so that no load is applied on the
fiber. (Excluding FT-H35-M2, FT-H35-M2S6, FD-H35-M2
and FD-H35-M2S6)

For a allowable bending radius of 25 mm (0.984 in)

Use of heat-resistant type fiber

•

Use by keeping 150 mm

5.906 in

, or more, of the heat-

resistant fiber cable part at normal temperature.