Fx-301 – Panasonic Digital Fiber Sensor FX-301 User Manual

Page 35

Advertising
background image

• Protect the amplifier from heat radiation or hot air.
• With the 350 ЊC

662 °F

heat-resistant type fiber, the

surface of the fiber head or the spiral may be discolored

by heat. However, this does not affect its performance.

102

FX-301

Connection with reflective coaxial type fiber
• With reflective coaxial type fiber, insert the center fiber

cable (single-core) into the beam-emitting inlet and the
outer fiber cable (multi-core) into the beam-receiving inlet.

FD-H35-M2 or FD-H20-M1 is marked ‘P’ on the beam-
emitting fiber cable and ‘D’ on the beam-receiving fiber cable.

FD-WG4, FD-WSG4 and FD-G4, FD-G6, FD-G6X are
composed of beam-emitting and beam-receiving fiber
cables that are different in diameter.

FD-G500, FD-EG1, FD-EG2, FD-EG3, FD-E22,
FD-H20-21 and FD-ENM1S1 are marked P on the
beam-emitting fiber cable.

Fiber cable bending radius
• If the fiber cable is bent at a smaller bending radius than allowable

bending radius, the sensing range decreases due to beam attenuation.

Fiber

Note: Please note that the 350 °C

662 °F

heat-resistant fibers, vacuum-
resistant and chemical-resistant
fibers cannot bend less than the
allowable bending radius.

Notes: 1) In case the fiber cables are not inserted to a position where they

stop, the sensing range reduces.

Notes:

2) Before connecting fiber cables to the amplifier, mount the fiber

attachments on their ends.

PRECAUTIONS FOR PROPER USE

.

Take care that, since the aperture angle of this product is very

narrow, the beam may not be received depending upon the setting.
At the time of installation, determine a reference plane, as shown in
the figure below, and taking sufficient care against beam
misalignment or tilt, install the emitting and receiving fibers so that
they are parallel.

<

FT-K8

>

Narrow beam type fiber mounting

Install the fiber using M3
countersunk head screws.
The tightening torque should
be 0.3 N

⅐m or less.

Further, when using the fiber
at places having intense
vibrations, use a screw-
locking adhesive, etc.

If mineral oil or solvent containing mineral oil component
adheres to the sensing surface, the lens may be
deformed. Take sufficient care to handle them.

Take care that, since the aperture angle of this product is

very narrow, the beam may not be received depending
upon the setting.
At the time of installation, determine a reference plane, as
shown in the figure below, and taking sufficient care
against beam misalignment or tilt, install the beam-
emitting and receiving fibers so that they are parallel.

Thru-beam type wide beam fiber mounting

<

FT-KV8 / FT-WKV8

>

How to bend sleeve

The bending radius must be R10 mm

R0.394 in

or more.

Please bend gradually using the fiber bender (FB-1) or a
round bar of "20 mm

"

0.787 in

or more.

Note: Do not bend the sleeve of side-view type, narrow beam type, narrow-

view type and ultra-small diameter type fiber.

Method of fixing fiber cable

If fixing the fiber cable in position, make sure that it is set in
a manner as shown below, so that no load is applied on the
fiber. (Excluding FT-H35-M2, FT-H35-M2S6, FD-H35-M2
and FD-H35-M2S6)

For a allowable bending radius of 25 mm (0.984 in)

Use of heat-resistant type fiber

Use by keeping 150 mm

5.906 in

, or more, of the heat-

resistant fiber cable part at normal temperature.

08/2005