Fx-301 – Panasonic Digital Fiber Sensor FX-301 User Manual

Page 38

Advertising
background image

105

FX-301

Fiber

PRECAUTIONS FOR PROPER USE

.

FT-L8Y/V8Y chemical-resistant type fiber

Do not use it in the following chemicals:
Dissolved alkali metals (Natrium, Potassium or Lithium),
Fluorine gas (F

2

), CIF

3

, OF

2

(including gaseous state).

The beam axis mark is indicated on the side-view fiber.

Perform the beam alignment with the beam axis marks, on
the receiver and the emitter, facing each other.

Use a commercial Fluorine resin
joint to mount the fiber.

The bending radius of the protective
jacket should be R30 mm

1.181 in

or more. It will be damaged under
the value.

The bending radius of the bear

fiber should be R25 mm

R0.984 in

or more. The sensing range will be
shortened under the value.

Do not subject the fiber under tension.

Although the chemical-resistant type fiber is rated for use
up to

ם

115 °C

ם

239 °F

, place 100 mm

3.937 in

or more

of the fiber in the normal temperature area to protect the
amplifier.

FD-F8Y liquid level sensing fiber

• Use a commercially available fluorine resin joint, etc., to

install FD-F8Y.

Mounting

Mounting

Cautions

• Take care that unclear liquid may not be sensed stably.
• Take care that the tube may stretch by maximum 2 % of

the total length if it is used at a high temperature.

• Do not scratch the fiber jacket while cutting the fluorine

resin tube.