Fx-301, Fiber precautions for proper use – Panasonic Digital Fiber Sensor FX-301 User Manual

Page 37

Advertising
background image

104

FX-301

Fiber

PRECAUTIONS FOR PROPER USE

.

Fiber cutter (FX-CT2)

To cut the fiber cables, insert them from the direction shown below.

(Fiber cable insertion direction)

1 Slide part of the fiber cutter fully upward till it stops.
2 Insert the fiber cables, mounted in the attachment, till

they stop.

Take care that there are separate fiber insertion cable
holes for "2.2 mm

"

0.087 in

and "1.0 mm

"

0.039 in

or

"

1.3 mm

"

0.051 in

fiber cables.

3 Slide part of the fiber cutter down to cut the fibers.

Notes: 1) The fiber cables should be cut in one stroke.

Notes:

2) Once a fiber cable is cut off at a hole, do not use the hole again. If

used, it degrades the cut surface quality and the detectability may
deteriorate.

Notes:

3) The blade cannot be replaced. Please purchase an additional fiber

cutter, if required.

Notes:

4) Note that the sensing range may be reduced by up to 20 %

depending on the cut condition. Hence, decide the setting distance
by taking sufficient margin.

How to use fiber cutter (FX-CT2)

(

)

Seal type slit mask for FT-WA30/A30, FT-WA8/A8
• Two types of slit masks are enclosed. (one type for

FT-A30 and FT-WA30) Apply the enclosed slit mask when
detecting small objects or as measures not to saturate the
emitted light amount for short-range sensing.
However, the sensing range is reduced when the slit mask
is mounted.
As the slit mask is seal type, stick it by aligning the
projection of the slit mask with the upper portion of the
fiber head, as shown in the figure below.

Sensing range when mounting slit mask [with FX-301(P)]

Mounting

Slit masks

FT-WA30/A30: 2,500 mm

98.425 in

(LONG) / 1,000 mm

39.370 in

(STD) / 600 mm

23.622 in

(FAST) / 200 mm

7.874 in

(S-D)

FT-WA8/A8: 400 mm

15.748 in

(LONG) / 200 mm

7.874 in

(STD) / 140 mm

5.512 in

(FAST) / 70 mm

2.756 in

(S-D) (0.5

ן

12 mm

0.020

ן

0.472 in

slit mask)

FT-WA8/A8: 800 mm

31.496 in

(LONG) / 400 mm

15.748 in

(STD) /

280 mm

11.024 in

(FAST) / 140 mm

5.512 in

(S-D)

(1

ן

12 mm

0.039

ן

0.472 in

slit mask)

Vacuum type fiber

Leakage: 1.33

ן

10

–10

Pa

⅐m

3

/sec. [He] or less

1 Make two holes on the vac-

uum tank wall (chamber
wall or flange).

Note: The hole diameter must be from

"

5.5 to " 6.0 mm

"

0.217 to

"

0.236 in

.

2 Mount the FV-BR1 photo-terminal on the vacuum tank

wall.

Notes: 1) The attached O-ring must be mounted.

Notes:

2) The O-ring must be used at the atmospheric side.

Notes:

3) The tightening torque should be 0.58 N

⅐m or less.

3 Mount the FT-J6 atmospher ic side fibers on the

atmospheric side of the FV-BR1 photo-terminals.

Notes: 1) The fixing nuts must be tightened securely. If not, the sensing

range may decrease.

Notes:

2) The tightening torque should be 0.58 N

⅐m or less.

4 Mount the vacuum type fibers on the vacuum side of the

FV-BR1 photo-terminals.

Notes: 1) The fixings rings of the vacuum type fibers must be tightened

securely. If not, the sensing range may decrease.

Notes:

2) The tightening torque should be 0.58 N

⅐m or less.

5 Fix the fiber head of the vacuum type fiber.

Note: The maximum tightening torque should be as given below.

Tightening torque

0.29 N

⅐m

0.58 N

⅐m

M2.6

M4
M6

Configuration

Mounting

A

A

08/2005