Fx-301-f, Order guide, Options – Panasonic Digital Fiber Sensor FX-301 User Manual

Page 57: Specifications

Advertising
background image

520

FX-301-F

ORDER GUIDE

FD-F7 series, FT-F9 series

12 to 24 V DC

ע

10 % Ripple P-P 10 % or less

Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)

NPN open-collector transistor

• Maximum sink current: 100 mA (50 mA, if five, or more,

amplifiers are connected in cascade.)

• Applied voltage: 30 V DC or less (between output and 0 V)

• Residual voltage: 1.5 V or less [at 100 mA (50 mA, if five, or

more, amplifiers are connected in cascade.) sink current]

Leak setting (F7 mode): OFF with detection of leak, Liquid setting (F9 mode): Using the jog switch, choose the signal OFF condition between absence of liquid and presence of liquid.

Incorporated

250!s or less (Note 1)

Individual teaching / Collective teaching

Orange LED (lights up when the output is ON)

Green LED [lights up during liquid setting (F9 mode)]

RUN: Green LED, TEACH

⅐ ALL ⅐ ADJ ⅐ DISP ⅐ OUT: Yellow LED

4 digit red LED display

Incorporated

Delay timer [used only for liquid setting (F9 mode)] (Timer setting selectable from 10 ms, 100 ms, 1,000 ms, and none)

0 to

ם

50

ЊC

ם

32 to

ם

122

ЊF

(If 8 to 16 units are connected in cascade: 0 to

ם

45

ЊC

ם

32 to

ם

113

ЊF

(No dew condensation), Storage:

מ

20 to

ם

70

ЊC

מ

4 to

ם

158

ЊF

35 to 85 % RH, Storage: 35 to 85 % RH

Sunlight: 10,000 ?x at the light-receiving face, Incandescent light: 3,000 ?x at the light-receiving face

EN 50081-2, EN 50082-2, EN 60947-5-2

1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 2)

20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 2)

10 to 150 Hz frequency, 0.75 mm

0.030 in

amplitude in X, Y and Z directions for two hours each

98 m/s

2

acceleration (10 G approx.) in X, Y and Z directions for five times each

Red LED (modulated)

Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Switch: Acrylic

Connector (Note 3)

Extension up to total 100 m

328.084 ft

is possible with 0.3 mm

2

, or more, cable.

20 g approx.

PNP open-collector transistor

• Maximum source current: 100 mA (50 mA, if five, or

more, amplifiers are connected in cascade.)

• Applied voltage: 30 V DC or less (between output and

ם

V)

• Residual voltage: 1.5 V or less [at 100 mA (50 mA, if five, or

more, amplifiers are connected in cascade.) source current]

OPTIONS

End plates

Appearance

Model No.

Description

MS-DIN-E

When cascading multiple amplifiers, or when it moves depending
on the way it is installed on a DIN rail, these end plates ensure
that all amplifiers are mounted together in a secure and fully
connected manner.

Amplifier mounting
bracket

MS-DIN-2

Fiber sensor amplifier
protection seal

FX-MB1

Designation

Model No.

Description

MS-DIN-2

Mounting bracket for amplifier

Amplifier mounting bracket

FX-MB1

10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplifier, as well as, prevents effect on another amplifier.
Connector seal:
It prevents contact of any metal, etc., with the pins of the quick-
connection cable.

Fiber sensor amplifier
protection seal

FX-301-F

Applicable fibers

Supply voltage

Power consumption

Output

Output operation

Short-circuit protection

Response time

Sensitivity setting

Operation indicator

Model indicator

MODE indicator

Digital display

Fine sensitivity adjustment function

Timer function

Ambient temperature

Ambient humidity

Ambient illuminance

EMC

Voltage withstandability

Insulation resistance

Vibration resistance

Shock resistance

Emitting element

Material

Connecting method

Cable extension

Weight

Item

Model No.

NPN output

FX-301P-F

PNP output

Type

SPECIFICATIONS

En

vironmental resistance

Notes: 1) When detecting leak (output OFF) during leak setting (F7 mode), since the sensor flashes the emitted light, only the response action for turning the signal back to ON is delayed (1 sec. approx.).

Notes:

2) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.

Notes:

3) The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below.

Main cable (3-core): CN-73-C1 (cable length 1 m

3.281 ft

), CN-73-C2 (cable length 2 m

6.562 ft

), CN-73-C5 (cable length 5 m

16.404 ft

)

Sub cable (1-core): CN-71-C1 (cable length 1m

3.281 ft

), CN-71-C2 (cable length 2 m

6.562 ft

), CN-71-C5 (cable length 5 m

16.404 ft

)

End plates are not supplied with the amplifier. Please order it separately when the amplifiers are mounted in cascade.

Two pcs. per set

08/2005