Fx-301, List of fibers – Panasonic Digital Fiber Sensor FX-301 User Manual

Page 9

Advertising
background image

76

FX-301

100

3.937

50

1.969

35

1.378

מ

44

1.732

22

0.866

14

0.551

מ

100

3.937

50

1.969

35

1.378

מ

72

2.835

36

1.417

26

1.024

מ

320

12.598

160

6.299

120

4.724

מ

160

6.299

80

3.150

50

1.969

מ

120

4.724

60

2.362

35

1.378

מ

100

3.937

50

1.969

30

1.181

מ

36

1.417

18

0.709

12

0.472

מ

50

1.969

25

0.984

18

0.709

מ

22

0.866

11

0.433

7

0.276

מ

50

1.969

25

0.984

18

0.709

מ

32

1.260

16

0.630

10

0.394

מ

160

6.299

80

3.150

60

2.362

מ

160

6.299

80

3.150

50

1.969

מ

80

3.150

40

1.575

25

0.984

מ

46

1.811

23

0.906

16

0.630

מ

18

0.709

9

0.354

6

0.236

מ

"

0.04 mm

"

0.0016 in

opaque object

"

0.02 mm

"

0.0008 in

opaque object

"

0.04 mm

"

0.0016 in

opaque object

"

0.06 mm

"

0.0024 in

opaque object

"

4 mm

"

0.157 in

opaque object

"

0.08 mm

"

0.003 in

opaque object

"

0.02 mm

"

0.0008 in

opaque object

LIST OF FIBERS

En

vironment resistant

Heat-resistant

V

acuum

Chemical-resistant

Environment resistant fibers [Thru-beam type (one pair set)]

:LONG
:STD

:FAST
:S-D

Sensing range (mm

in

) (Note 1)

Red LED

Blue LED Green LED Infrared LED

550

21.654

280

11.024

200

7.874

100

3.937

200

7.874

300

11.811

1,000

39.370

1,000

39.370

280

11.024

165

6.496

75

2.953

90

3.543

310

12.205

140

5.512

50

1.969

880

34.646

440

17.323

155

6.102

550

21.654

280

11.024

90

3.543

3,500

137.795

1,500

59.055

530

20.866

470

18.504

230

9.055

80

3.150

220

8.661

100

3.937

35

1.378

800

31.496

400

15.748

140

5.512

3,500

137.795

1,500

59.055

530

20.866

420

16.535

210

8.268

160

6.299

מ

220

8.661

110

4.331

70

2.756

מ

420

16.535

210

8.268

160

6.299

מ

70

2.756

35

1.378

25

0.984

מ

320

12.598

160

6.299

120

4.724

מ

400

15.748

200

7.874

150

5.906

מ

75

2.953

38

1.496

24

0.945

מ

70

2.756

35

1.378

22

0.866

מ

28

1.102

14

0.551

10

0.394

מ

Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared

type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.

Notes:

2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using amplifiers other than red

LED type. The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent condition.

Notes:

3) The allowable cutting range is 500 mm

19.685 in

from the end that the amplifier inserted.

Lens mountable

Side-view

350

ЊC

662

ЊF

Lens mountable

200

ЊC

392

ЊF

Lens mountable

130

ЊC

266

ЊF

Lens mountable

Easy mounting

⅐ Rectangular head

SEMI S2 compliant
W7

ן

H15

ן

D13

W0.276

ן

H0.591

ן

D0.512

350

ЊC

662

ЊF

Sleeve 60 mm

2.362 in

Allows flexible wiring
200

ЊC

392

ЊF

Lens mountable

R25 mm

R0.984 in

R25 mm

R0.984 in

R25 mm

R0.984 in

R30 mm

R1.181 in

R200 mm

R7.874 in

R30 mm

R1.181 in

FT-H35-M2

FT-H35-M2S6

FT-H20W-M1

FT-H20W-M2

FT-H20-M1

FT-H13-FM2

FT-L8Y

FT-V8Y

FT-6V

FT-60V

Allowable
bending
radius

Model No.

R10 mm
R0.394 in

R10 mm
R0.394 in

FT-Z802Y

The vacuum type fiber must be used with the following products as a set.

FT-J6: Fiber at atmospheric side (one pair set) FV-BR1: Photo-terminal (one pair set)

Semi-standard fibers (Custom made per order)

The fiber cable length or sleeve length of the standard fibers can be modified at your request. Select the fiber cable length (symbol

ଁ ) or the sleeve length

(symbol f ) from the table below.

FT-FM

FT-FM

-S f

FT-FM

L

FT-NFM2-S f

FT-WA30-

FT-WA8-

FT-A30-

FT-A8-

FT-H20-M

FT-H35-M

FT-Z80

Y

3

9.843

, 4

13.123

, 5

16.404

, 10

32.808

,

15

49.213

, 20

65.617

,25

82.021

, 30

98.425

2

6.562

(Note), 3

9.843

, 4

13.123

, 5

16.404

,

10

32.808

, 15

49.213

, 20

65.617

, 25

82.021

, 30

98.425

20

65.617

, 30

98.425

5

16.404

2

6.562

, 3

9.843

3

9.843

5

16.404

, 7

22.966

Standard threaded
head (free-cut)

With sleeve

With large diameter lens

Small diameter threaded
head with sleeve (free-cut)

Wide beam

200

ЊC

392

ЊF

heat-resistant

350

ЊC

662

ЊF

heat-resistant

Chemical-resistant

Correlation between sensing
range attenuation coefficient and
fiber cable length

The longer the fiber cable, the shorter the
sensing range.

1

0.394

, 2

0.787

, 3

1.181

, 4

1.575

, 5

1.969

, 6

2.362

,

7

2.756

, 8

3.150

, 9

3.543

, 10

3.937

, 11

4.331

, 12

4.724

1

0.394

, 2

0.787

, 3

1.181

, 4

1.575

, 5

1.969

, 6

2.362

,

7

2.756

, 8

3.150

, 9

3.543

, 10

3.937

, 11

4.331

, 12

4.724

Note: The standard fiber has a 2 m

6.562 ft

fiber cable length and a 4 cm

1.575 in

or 9 cm

3.543 in

sleeve length.

Fiber

R25 mm

R0.984 in

Sleeve

Type

Shape of fiber head

(mm

in

)

2 m

6.562 ft

1 m

3.281 ft

2 m

6.562 ft

1 m

3.281 ft

1 m

3.281 ft

Type

ଁ Fiber cable length

(Unit: m

ft

)

f

Sleeve length

(Unit: cm

in

)

Min. sensing object

under the optimum
condition (Note 2)

Basic model No.

2 m

6.562 ft

2 m

6.562 ft

2 m

6.562 ft

(Note 3)

Fiber cable
length

: Free-cut

08/2005

Advertising