Fx-301-f, Precautions for proper use – Panasonic Digital Fiber Sensor FX-301 User Manual

Page 60

Advertising
background image

523

FX-301-F

PRECAUTIONS FOR PROPER USE

Individual teaching mode

Part description

• The sensitivity selection function is set to the automatic

sensitivity setting ( ) at the time of factory shipment. In
case sensitivity selection setting is done, make sure to carry
out ‘teaching’ after the sensitivity selection setting.

For the sensitivity selection setting, refer to ‘Sensitivity
selection function
’ on p.525.

Insert Leak detection fiber
(FD-F7

Ⅺ ) or Liquid

detection fiber (FT-F9

Ⅺ).

Press MODE key to light
up MODE indicator /
TEACH (yellow).

Turn the jog switch to ‘

ם

’ or

מ

’ side to set to either Leak

(F7) mode ( ) or Liquid
(F9) mode (

).

In case Liquid (F9) mode
(

) is set, the model

indicator (Green) lights up.

Press Jog switch in no-leak
condition with Leak detection
fiber (FD-F7

Ⅺ ) or no-liquid

condition with Liquid detection
fiber (FT-F9

Ⅺ). Then, ‘

’ on

the display moves from left to
right.

When teaching is accepted, the result of threshold
value setting is displayed.

• In case stable sensing is possible: ‘

’ on the

display blinks three times.

• In case stable sensing is not possible: ‘

’ on

the display blinks. (Note 1)

If the teaching result is ‘

’, the sensor returns to

RUN mode automatically and the incident light
intensity is shown on the display.
MODE indicator / RUN (green) lights up.
The setting is complete.

• When MODE indicator / TEACH (yellow) lights up, threshold value

can be set on a single unit.

1

2

3

4

5

Step

Description

Display

Notes: 1) For details, refer to ‘Error indication’ on p.526.

Notes:

2) The initial setting at the time of factory shipment is Liquid (F9)

mode (

).

Notes:

3) Do not move or bend the fiber cable after the sensitivity setting.

Detection may become unstable.

1 Operation indicator (Orange)… Lights up when output is ON.
2 Model indicator (Green)… Lights up during liquid setting (F9 mode).
3 MODE indicators…

RUN (Green) : Lights up during normal sensing

operation.

TEACH (Yellow): Lights up when the individual

teaching mode is selected.

ALL (Yellow) : Lights up when the collective

teaching mode is selected.

ADJ (Yellow) : Lights up when the threshold value

fine adjustment mode is selected or
the sensitivity switching function is
activated.

DISP (Yellow): Lights up when the digital display

setting mode is selected or the timer
function is activated.

OUT (Yellow) : Lights up when the forced output

mode is selected or the NO / NC
switching function is activated.

4 Jog switch... Moving this switch in the ‘

ם

’ or ‘

מ

’ direction,

allows different items to be viewed for selection
and pressing the switch then confirms the selected
setting.

5 MODE key... This key is used to select operating modes and to

cancel settings during the configuration process.

Setting items

How to change to ‘percent display’

RUN Mode

• When MODE indicator / RUN (green) lights up, the display setting or the

sensitivity select setting can be checked. Refer to ‘Sensitivity selection
function
’ on p.605 for further details of sensitivity select setting.

• When Jog switch is pressed for 2 sec., or more, the display

changes as per the diagram below.

How to check the sensitivity state

• If Jog switch is turned to ‘

ם

’ or ‘

מ

’ side, the present sensitivity state can be

confirmed. After 2 sec., the display returns to ‘digit display’ or ‘percent display’.

08/2005

Advertising