PRECAUTIONS FOR PROPER USE

Individual teaching mode

Part description

• The sensitivity selection function is set to the automatic

sensitivity setting ( ) at the time of factory shipment. In
case sensitivity selection setting is done, make sure to carry
out ‘teaching’ after the sensitivity selection setting.

•

For the sensitivity selection setting, refer to ‘Sensitivity
selection function
’ on p.525.

Insert Leak detection fiber
(FD-F7

Ⅺ ) or Liquid

detection fiber (FT-F9

Ⅺ).

Press MODE key to light
up MODE indicator /
TEACH (yellow).

Turn the jog switch to ‘

ם

’ or

‘

מ

’ side to set to either Leak

(F7) mode ( ) or Liquid
(F9) mode (

).

In case Liquid (F9) mode
(

) is set, the model

indicator (Green) lights up.

Press Jog switch in no-leak
condition with Leak detection
fiber (FD-F7

Ⅺ ) or no-liquid

condition with Liquid detection
fiber (FT-F9

Ⅺ). Then, ‘

’ on

the display moves from left to
right.

When teaching is accepted, the result of threshold
value setting is displayed.

• In case stable sensing is possible: ‘

’ on the

display blinks three times.

• In case stable sensing is not possible: ‘

’ on

the display blinks. (Note 1)

If the teaching result is ‘

’, the sensor returns to

RUN mode automatically and the incident light
intensity is shown on the display.
MODE indicator / RUN (green) lights up.
The setting is complete.

• When MODE indicator / TEACH (yellow) lights up, threshold value

can be set on a single unit.

1

2

3

4

5

Step

Description

Display

Notes: 1) For details, refer to ‘Error indication’ on p.526.

Notes:

2) The initial setting at the time of factory shipment is Liquid (F9)

mode (

).

Notes:

3) Do not move or bend the fiber cable after the sensitivity setting.

Detection may become unstable.

1 Operation indicator (Orange)… Lights up when output is ON.
2 Model indicator (Green)… Lights up during liquid setting (F9 mode).
3 MODE indicators…

RUN (Green) : Lights up during normal sensing

operation.

TEACH (Yellow): Lights up when the individual

teaching mode is selected.

ALL (Yellow) : Lights up when the collective

teaching mode is selected.

ADJ (Yellow) : Lights up when the threshold value

fine adjustment mode is selected or
the sensitivity switching function is
activated.

DISP (Yellow): Lights up when the digital display

setting mode is selected or the timer
function is activated.

OUT (Yellow) : Lights up when the forced output

mode is selected or the NO / NC
switching function is activated.

4 Jog switch... Moving this switch in the ‘

ם

’ or ‘

מ

’ direction,

allows different items to be viewed for selection
and pressing the switch then confirms the selected
setting.

5 MODE key... This key is used to select operating modes and to

cancel settings during the configuration process.

Setting items

How to change to ‘percent display’

RUN Mode

• When MODE indicator / RUN (green) lights up, the display setting or the

sensitivity select setting can be checked. Refer to ‘Sensitivity selection
function
’ on p.605 for further details of sensitivity select setting.

• When Jog switch is pressed for 2 sec., or more, the display

changes as per the diagram below.

How to check the sensitivity state

• If Jog switch is turned to ‘

ם

’ or ‘

מ

’ side, the present sensitivity state can be

confirmed. After 2 sec., the display returns to ‘digit display’ or ‘percent display’.