INSTALLATIONS (PS

Data)

The installation should be made by qualified service personnel or system installers according to the following instructions.

CAUTION

System Connections

Connection Example

Example 1 shows 8 cameras connected to 2 Data Multiplex Units (WJ-MP204C), to a Video Multiplexer (e.g., WJ-FS316) and a
Digital Disk Recorder (e.g., WJ-HD100). The WV-CU360C controls these system units through RS-485 communication while
pictures are viewed on the monitors.

SIGNAL

GND

ALARM/REMOTE

OUT

IN

VIDEO

16

15

14

13

12

11

10

9

8

16

15

14

13

12

11

10

9

8

7

6

5

4

2

1

7

6

5

4

3

3

2

1

PLAY IN

REC OUT

SPOT OUT

DATA

CAMERA

SW IN

MULTI
SCREEN OUT

SD

RD

IN

IN

CAMERA

RS485

A

B

A

B

G

VS/VD

SPOT

DATA

A L A R M / R E M OT E

MODE

SIGNAL GND

4

3

2

1

OUT

OUT

IN

OUT

4

3

2

1

T

R

IN

IN

CAMERA

RS485

A

B

A

B

G

VS/VD

SPOT

DATA

A L A R M / R E M OT E

MODE

SIGNAL GND

4

3

2

1

OUT

OUT

IN

OUT

4

3

2

1

Camera No. 1

Camera No. 2

Camera No. 3

Camera No. 4

Camera No. 5

Camera No. 6

Camera No. 7

Camera No. 8

VS/VD INPUT

Unit Address 1

Unit Address 2

WJ-MP204C

WJ-MP204C

WJ-FS316

WJ-HD100

Unit Address 3

Unit Address 4

Video Signal

6-conductor Modular Cable (supplied)

Termination ON

MODE

VS/VD OUTPUT

4-Line

Monitor No. 1

Monitor No. 2

Panasonic Security
Data mode

Termination OFF

Panasonic Security
Data mode

4-Line

MODE

VD OUT

RS-485 Signal
(Panasonic Security
Data Mode)

SIGNAL GND

ALARM

SERIES

RECORD

TIME

ADJUST

REMOTE

MODE

DATA

RS-232C

VIDEO

OUT

IN

OUT

IN

AUDIO

MONITOR OUT

(PLAY)

CAMERA
SW OUT

G

G

G

POWER

ON

OFF

JOG-CLICK

JOG-LEFT

JOG-RIGHT

ALARM SEARCH

STEP

REW/FF

STOP/SETUP

PLAY

REC

OUT

PLAY OUT

REC OUT

AUTO OFF OUT

DISK END OUT

IN

OUT

IN

RECALL

(EXT REC)

OUT

RECOVER OUT

RESET IN

IN

PLAY IN

PLAY

VIDEO IN

REC OUT

RS-485 Cable

Branch
Cable

Up to four WV-CU360C
can be used in a system.

DC 9V IN

DATA

MODE

CONTROLLER No.

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

Keep in OFF position

Keep in OFF position

Termination ON

Set to OFF position
(for operator mode)

Controller No. 1

Refer to DIP switch setting on page 15

CONTROLLER No.