Controller number setting, Switch setting procedures, Controller no – Panasonic WV-CU360C User Manual

Page 57

Advertising
background image

59

Controller Number Setting

Set this switch always to 1 when using the System
Controller with the WJ-SX350.

Switch Setting Procedures

Set the MODE DIP switch and CONTROLLER NO. switch as
follows.

1. Remove the DC plug from the rear of the controller.

2. Set the MODE switches.

Bit 1 through 3 should match the version of the WJ-
SX350 installed in your system. Open the SETUP MENU
of the WJ-SX350 and check the version shown in the
upper right corner of the menu.

For version 6.00 or later, set the switches as shown
below.

• Bit 1 should be set to OFF*.
• Bit 2 should be set to ON.
• Bit 3 should be set to ON.

S E T U P M E N U 6.xx/1.xx

P R O G R A M

O P E R A T O R

S Y S T E M

C A M D A T A L O A D

C A M E R A T I T L E

C A M – P O S I M A P

F U N C T I O N K E Y

MODE

1

2

3

4

5

6

7

8

OFF

ON

For version 1.xx, set the switches as shown below.

• Bit 1 should be set to OFF*.
• Bit 2 should be set to ON.
• Bit 3 should be set to OFF*.

Bits 4 through 8 are not version related.

• Bit 4 should be set to OFF*.
• Bit 5 should be set to ON*.
• Bit 6 should be set to OFF* (Operator) normally, or

ON (Administrator) when setting up the controller.

• Bit 7 should be set to OFF*. Baud rate selection is

automatic.

• Bit 8 should be set to OFF* normally.

3. Connect the DC plug to the controller.

MODE

1

2

3

4

5

6

7

8

OFF

ON

0

9

8

7

6

5

4

3

2

1

CONTROLLER No.