Dip switch setting, Controller number setting, Switch setting procedures – Panasonic WV-CU360C User Manual

Page 70: Controller no

Advertising
background image

72

Controller Number Setting

Set this switch always to 1 when using the System
Controller in a System 850.

Switch Setting Procedures

Set the MODE DIP switch and CONTROLLER NO. switch as
follows.

1. Remove the DC plug from the rear of the controller.

2. Set the switches as follows.

• Bit 1 should be set to OFF*.
• Bit 2 should be set to ON.
• Bit 3 should be set to OFF*.
• Bit 4 should be set to OFF*.
• Bit 5 should be set to ON* when connecting with a

System 850 in a home run (one to one) fashion.

• Bit 6 should be set to OFF* (Operator) normally, or ON

(Administrator) when setting up the controller.

• Bit 7 should be set to ON. The baud rate is selected in

the controller setup.

• Bit 8 should be set to OFF* normally.

3. Connect the DC plug to the controller.

SW position

OFF

See below

See below

See below

Not used

On*

Administrator

Set up from CU360

3 times

Function

ON

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

System ID

System ID

System ID

Reserved

Line termination

Operation mode

Baud Rate Selection

Repeat Transmissions

*

*

*

*

Off

Operator*

Auto-selection*

1 time*

MODE

1

2

3

4

5

6

7

8

OFF

ON

0

9

8

7

6

5

4

3

2

1

CONTROLLER No.

DIP Switch Setting

An 8-bit DIP switch mounted on the rear panel specifies communication mode, etc. The default position is marked with an
asterisk *.