Administrator authorization, Baud rate, Parity – Panasonic WV-CU360C User Manual

Page 19: Wait time, Controller unit-group address, System unit-group address

Advertising
background image

19

●

Administrator Authorization

1. Press the CAM/SET button while [SEtUP] is displayed.

The [- - - - -] prompt appears.

2. Enter a password with the numeric buttons, then press

the CAM/SET button.
The default setting is [12345].

3. [SPEED] appears when the right password is entered. If

password entry failed, the menu returns to [- - - - -].

Notes:

• We recommend that you register a new password dif-

ferent from “12345” in [SUSrP], and note down the reg-
istered password for future reference.

• Powering up the controller while holding down numeric

buttons 2, 4 and 5 simultaneously will reset the pass-
word to “12345”. Remember that this procedure also
resets all other menu parameters to the default settings.

●

Baud Rate

In this menu, the communication speed (bps: bits per sec-
ond) is selected. The communication speed should match
that of the other units connected in the communication
chain.

1. Display [SPEED] and press the CAM/SET button twice.

2. Select a parameter entering a bracket-enclosed num-

ber, e.g., (3), moving the joystick right and left, or
pressing the [+] and [–] button.
The default setting is 19 200 bps.

(1) 2 400:

2 400 bps

(2) 4 800:

4 800 bps

(3) 9 600:

9 600 bps

(4) 19 200:

19 200 bps

Note:

Selecting a slower rate (e.g., 2 400 bps) will

delay the response time (e.g., the time until an acti-
vated alarm is reset).

3. Press the CAM/SET button to validate the selection.

4. Press the ESC button to go back to the previous menu.

●

Parity

In this menu, the parity check mode is selected.

1. Display [PrtY] and press the CAM/SET button twice.

2. Select a parameter with the joystick.

The default setting is None.

n:

None

E:

Even parity

3. Press the CAM/SET button to validate the selection.

4. Press the ESC button to go back to the previous menu.

●

Wait Time

In this menu a wait time is selected. The controller will
retransmit data when there is no response during the speci-
fied wait time.

1. Display [LJAit] and press the CAM/SET button twice.

2. Select a parameter with the joystick.

The default setting is Off.

(1) OFF:

Off, no retransmission of data

(2) 100:

100 ms

(3) 200:

200 ms

(4) 400:

400 ms

(5) 500:

500 ms

(6) 1 000:

1 s

3. Press the CAM/SET button to validate the selection.

4. Press the ESC button to go back to the previous menu.

The following two menus should be maintained in the
default condition.

●

Controller Unit-Group Address

[CU-gr] appears on the Setup menu, but leave the
default as it is.

●

System Unit-Group Address

[SU-gr] appears on the Setup menu, but leave the
default as it is.