MODE Switch Setting for System Example 2

The MODE switch needs to be set prior to operating a sys-
tem connected as shown in Example 2.

Bit 3 should be set to OFF.
Bit 5 should be set to OFF when the controller is placed
in an intermediate position, or set to ON when it is con-
nected at the chain end.

Controller Number Setting (PS

Data)

A 10-position rotary switches provided on the rear for spec-
ifying the unit number of the WV-CU360C controller in a
PS

Data system.

1. Remove the DC plug from the rear of the controller.
2. Use a screw driver to rotate the switch so that the arrow

comes to the number you wish.

3. Connect the DC plug to the controller.

Notes:

• Set the switch to #1 when a single controller is used in

the system.

• Specify a unique number for each controller when con-

necting multiple controllers in the system. One con-
troller within the multiple controller system must be
assigned the number 1.

• Positions #0 and #9 are reserved and cannot be used.

0

9

8

7

6

5

4

3

2

1

CONTROLLER No.

Controller No. Switch of WV-CU360C

Controller No.

0

Reserved

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

Reserved

1

2

3

4

5

6

7

8

OFF

ON