Dip switch setting (ps• data), Dip switch setting (ps, Data) – Panasonic WV-CU360C User Manual

Page 15

Advertising
background image

15

SW position

• Daisy Chain Connection

DIP Switch Setting (PS

Data)

An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an
asterisk *.

DATA

Data Multiplex Unit

WJ-MP204C

Branch
Cable

Termination:
OFF

Termination:
ON

System Controller

WV-CU360C

DATA

DATA

Video Multiplexer

WJ-FS309 (WJ-FS316)

RS-485
Cable

Termination:
ON

RS-485
Cable

MODE

1

2

3

4

5

6

7

8

OFF

ON

OFF

Not used

Function

ON

Bit 6

Bit 7

Bit 8

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Operation mode

Baud rate selection

Data transmission mode

Line termination

Reserved

System Unit Version

System Unit Version

System Unit Version

Operator*

Fixed to OFF*

Fixed to OFF*

Off

Fixed to OFF*

Fixed to OFF*

Fixed to OFF*

Fixed to OFF*

Administrator

Not used

Not used

On*

Not used

Not used

Not used

1. Remove the DC plug from the rear of the controller.
2. Set the switch referring to the table.
3. Connect the DC plug to the controller.

Notes:

• Bits 1 - 4 are reserved.
• Bit 5 opens or terminates the communication chain. The switch should be set to OFF when the controller is located in an

intermediate position.

• Bit 6 specifies the operation mode, Operator or Administrator. The switch should be set to Administrator when setting up

the controller. Remember to set this switch to the right position after completion of the setup operation.

• Bits 7 and 8 are used in the OFF position.