Table 5-5, Switch settings for delay answer timing, vau -23, Table 5-6 – Panasonic CPC-EX User Manual

Page 117: Switch settings for dtmf detection timing, vau -23, Table 5-7

Advertising
background image

Section 300-Installation

Chapter 5. Peripheral Equipment

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

5-23

Table 5-7. Switch settings for delay answer timing, VAU

Table 5-8. Switch settings for DTMF detection timing, VAU

Table 5-9. Switch settings for wait timing between dialed digits, VAU

Switch Block 2 (SW2)
Delay Answer Timer (Switches 1-3)

Switch

Timer (in seconds)

4

8

12

16

20

24

28

No Answer
(VAU 1.1 or
below) or
Immediate
Answer (VAU
1.2 or above)

1

OFF OFF OFF OFF ON

ON

ON

ON

2

OFF OFF ON

ON

OFF OFF ON ON

3

OFF ON

OFF ON

OFF ON OFF ON

DTMF Detection Timer

VAU

Version

Switch

block and

switch

Function

1.1 or above

SW2, pin 4

ON=80 ms

OFF=40 ms

1.0 or below

SW1, pin 1
and SW2,
pin 4

Where X/X=SW1 setting/SW2 setting:

ON/ON=40
OFF/ON=60
ON/OFF=80
OFF/OFF=100

Switch Block 2 (SW2)
Wait Time Between Dialed Digits (Switches 5-6)

Switch

Time (in seconds)

2

6

10

14

5

OFF

OFF

ON

ON

6

OFF

ON

OFF

ON

Advertising