Section 300-Installation

Chapter 4. Trunks and Lines

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

4-37

Analog Extensions

Note: Normally analog extensions are supported using the AEC (VB-43621).
Alternatively, a Single Line Telephone Adaptor (SLTA, VB-43709) may be
used to support analog DTMF (2500 set) extensions. The SLTA converts up
to 4 digital ports to analog ports. See “Single Line Telephone Adaptor” on
page 5-34 for more
information.

Guidelines

• An MFR card (VB-43431) is required when the AEC is used. The MFR

card, which provides DTMF signals, includes eight circuits that are shared
among the analog extensions.

• The AEC also requires the SLT ringer box (VB-2089P).

Installation

1. Install the AEC cards in extension slots.

2. Install the MFR card in AUX1 or AUX2. If installing in a two-cabinet

system, see Chapter 6 for specific information for installing MFR card(s).

3. Install the SLT Ringer Box as shown in Figure 4-14. Be sure to note the

differences between the DBS 40 Connector Panel and the Connector
Panel on the DBS 72 and 96.