Cabling specifications, Cabling specifications -13, Table 7-11 – Panasonic CPC-EX User Manual

Page 155: Maximum cabling distances -13

Advertising
background image

Section 300-Installation

Chapter 7. Specifications

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

7-13

Cabling Specifications

Table 7-11. Maximum cabling distances

Loop Type and Resistance

Resistance

Cable Gauge
(AWG)

Maximum Cabling
Length in Feet
(Distance from the
DBS)

Key phone, EM/24

40 Ohms

22

1239

24

779

26

490

DSS/72 20

Ohms

22

619

24

388

26

244

SLT 100

Ohms

22

3097

24

1948

26

1225

OPX (Loop between the DBS and
the OPX Adaptor)

10 Ohms

22

309

24

194

26

122

OPX (Loop between the OPX
Adaptor and a pushbutton SLT)

900 Ohms

(excluding end

impedance)

22

27877

24

17532

26

11025

Doorphone (Loop between the
DBS and the Doorphone Adaptor)

10 Ohms

22

309

24

194

26

122

Doorphone (Loop between the
Doorphone Adaptor and the Door-
phone)

40 Ohms

22

1239

24

779

26

490

Voice Announce Unit

10 Ohms

22

309

24

194

26

122