Section 300-Installation

Chapter 4. Trunks and Lines

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

4-27

Installing T1 in a Double Cabinet with the T1 in the Slave

1. Install the Sync Unit in the master cabinet as described in Steps 1 and 2

under “Installation for a Single T1.”

2. Install a T1 MDF card in the slave cabinet. (See Step 3 on page 4-23.)

3. Set Switch 1 on the T1 card. (See Step 4 on page 4-24.)

4. Install a T1 card in the “EC/TRK” slot of the slave cabinet.

5. Connect the Sync Cable from CN1 on the Sync Unit to CN5 on the T1

card (Figure 4-11).

Note: Part Number VB-43564 is used for the Sync Cable when a T1 is
installed only in the slave cabinet of a two-cabinet system.

6. At the slave cabinet, connect the cable attached to CN3 on the T1 MDF

card to CN3 on the T1 card (Figure 4-10).

7. Using an RJ48 cable, connect CN1 of the T1 MDF card to the CSU. (See

Figure 4-9 on page 4-25 for RJ48 pinouts.)

8. At the slave cabinet, connect the ground cable on the T1 MDF card as

shown in Figure 4-10 on page 4-26.