Loop-start trunks, Loop-start trunks -7, Figure 4-2 – Panasonic CPC-EX User Manual

Page 55: L-trk card strap j1 and switch locations -7, Guidelines, Installation

Advertising
background image

Section 300-Installation

Chapter 4. Trunks and Lines

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

4-7

Loop-Start Trunks

Guidelines

• Two versions of the loop-start trunk are available: the four-port version

(VB-43510) and the eight-port version (VB-43511).

• The following procedure covers loop-start trunk installation using the main

trunk connector. For instructions on using the expansion trunk connector,
see “Trunk and Line Expansion” on page 4-44

• For pinouts and color codes for the main trunk connector, see Table 4-2 on

page 4-5.

Installation

Installation without Caller ID

1. If installing VB-43511A Loop Start Card:

a. Remove the cover from the L-TRK card (VB-43511A).

b. Set the all option switches to ON as shown in Figure 4-2.

c. Replace the cover on the L-TRK card (VB-43511A).

Figure 4-2. L-TRK Card Strap J1 and Switch Locations

ON

ON

O N

ON

ON

ON

ON

ON

O N

ON

L-TRK Card
(VB-43511A)

SW1

SW3

SW5

SW2

SW4

SW6

SW8

SW7

TK1

TK2

TK3

TK4

TK5

TK6

TK7

TK8

When a Caller ID Card Is Installed,
Set All Switches to the OFF Position

When No Caller ID Card Is Installed,
Set All Switches to the ON Position

J1

Strap J1
must be
cut to
receive
Caller ID

Advertising