Section 300-Installation

Chapter 5. Peripheral Equipment

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

5-35

Table 5-11. Maximum distances for SLTA installation

4. If the DBS is powered up, turn off the power.

5. Connect the GND and +24V leads on the SLTA to the DBS connector

panel. Be sure the wires do not touch each other or touch the metal
frame housing
.

6. Turn on the DBS power.

7. Connect the “T” and “R” leads to the digital extension ports on the DBS

as per Figure 5-21. One digital extension port is required for each SLT.

8. Connect the SLT “T” and “R” leads to the SLTs.

9. Install the cover on the SLTA.

Wiring
gauge

Max. distance (in feet) between
the DBS and SLTA

Max. distance (in feet) between
the SLTA and the SLT

AWG 22

300’ or 10 W

3000’ or 100 W

AWG 24

190’ or 10 W

1900’ or 100 W

AWG 26

120’ or 10 W

1200’ or 100 W