Chapter 2

Connecting Signals

NI PXI-4224 User Manual

2-2

ni.com

Caution

The PFI 0/CAL SMB connector is for low-voltage timing and calibration signals

only. Voltages greater than ±15 V can damage the device.

If you are building a 25-pin D-SUB connector for your application, make sure you use a
connector and wires that are safety rated for the voltage and category of the signals in your
application.

Table 2-1. NI PXI-4224 25-Pin D-SUB Terminal Pin Assignments

Front Connector

Diagram

Pin Number

Signal Names

Pin Number

Signal Names

*

NC—No Connection

14

AI 0 –

1

AI 0 +

15

AI 1 –

2

AI 1 +

16

AI 2 –

3

AI 2 +

17

AI 3 –

4

AI 3 +

18

AI 4 –

5

AI 4 +

19

AI 5 –

6

AI 5 +

20

AI 6 –

7

AI 6 +

21

AI 7 –

8

AI 7 +

22

No Pin

9

No Pin

23

NC

*

10

D GND

24

SPI CLK

11

MISO

25

SELECT

12

MOSI

N/A

N/A

13

+5 V

14

15

16

17

18

19

20

21

22

23

24

25

123456789

1

0

1

1

1

2

1

3