Table 5-2. programming a task in labview, Table 5-2, Programming a task in labview -6 – National Instruments Isolated Analog Input Device NI PXI-4224 User Manual
Page 42
 
Chapter 5
Using the NI PXI-4224
5-6
ni.com
Table 5-2. Programming a Task in LabVIEW
Flowchart Step
VI or Program Step
Create Task in DAQ Assistant
Create a
DAQmx Task Name Constant
located on the
Controls»All Controls»I/O»DAQmx Name Controls 
subpalette, right-click it, and select 
New Task (DAQ
Assistant)
.
Create a Task 
Programmatically 
(optional)
DAQmx Create Task.vi
located on Functions»
All Functions»NI Measurements»DAQmx - Data 
Acquisition»DAQmx Advanced Task Options—This VI is 
optional if you created and configured your task using the DAQ 
Assistant. However, if you use it in LabVIEW any changes you 
make to the task will not be saved to a task in MAX.
Create AI Voltage Channel 
(optional)
DAQmx Create Virtual Channel.vi
(AI Voltage by
default)—This VI is optional if you created and configured 
your task and channels using the DAQ Assistant.
Adjust Timing Settings 
(optional)
DAQmx Timing.vi
(Sample Clock by default)—This VI is
optional if you created and configured your task using the DAQ 
Assistant.
Configure Channels 
(optional)
DAQmx Channel Property Node—Refer to the
Channel Property Node in LabVIEW
section for more
information. This step is optional if you created and fully 
configured the channels in your task using the DAQ Assistant.
Start Measurement
DAQmx Start Task.vi
Read Measurement
DAQmx Read.vi
Analyze Data
Some examples of data analysis include filtering, scaling, 
harmonic analysis, or level checking. Some data analysis tools 
are located on the Functions»Signal Analysis subpalette and on 
the Functions»All Functions»Analyze subpalette.
Display Data
You can use graphical tools such as charts, gauges, and graphs 
to display your data. Some display tools are located on the 
Controls»Numeric Indicators subpalette and Controls»