12

Chapter 2 1005r server description

Server dimensions and weight

Height

87.6 mm (3.45 in.)

Width

435.3 mm (17.4 in.)

Depth (distance from front to back)

508 mm (20 in.)

Weight of fully loaded system

20 kg (44 lb)

Environmental specifications

Environmental condition

Specification

Operating temperature

5



C to 35



C (41



F to 95



F)

Maximum rate of change must not
exceed 10



C (50



F) per hour.

Non operating (storage) temperature

-40



C to +70



C (-40



F to +158



F)

Non operating humidity

95% @ 23 to 40



C

Altitude

< 1 829 m (6 000 ft)

Electrostatic discharge

<= 15 kV

Acoustic noise

< 55 dBA

Handling drop (storage)

18 in free-fall (when packaged)

Handling drop

2g 11 mS

Front clearance

50.8 mm (2 in.)

Side clearance

25 mm (1 in.)

Rear clearance

92 mm (3.6 in.)

Front panel controls and features

The following diagram shows the front view of the 1005r server chassis with
the bezel cover removed. When the bezel cover is on, only the DVD and
USB connections, controls, alarm LEDs, and status LEDs are visible. With
the bezel cover removed, both hard drives, the peripheral DVD/CD/CDRW
drive, the anti-static connection, and the front serial port are accessible.