Nortel Networks Server 1005r User Manual

Page 20

Advertising
background image

20

Chapter 2 1005r server description

In the previous illustration, the telephony LAN (TLAN subnet) provides
IP connectivity between the CS 1000 system and the i2004 Internet
phonesets. The connection between the call server and media gateway
can be point-to-point (or through the LAN), if the system is installed in
a distributed data network.

For information about the CS 1000 system and i2004 Internet phoneset
bandwidth and network requirements, refer to the Communication Server for
Enterprise 1000 Planning and Installation Guide
(553-3023-210).

Switch connectivity

For more details about how the 1005r server and switch connection
is established, refer to the Installation and Configuration Task List
(NN44200-306).

CallPilot ELAN subnet and Nortel server subnet setup

The 1005r server provides 10/100/1000Base-T Ethernet connectivity
through NICs installed in the server. The function of the NIC varies based
on switch connectivity, as follows:

Meridian 1 or CS 1000 systems

One NIC provides connectivity to the ELAN subnet. Connect the NIC
labeled NIC2-NickP on the back of the server to the ELAN subnet.

For information about the purpose and requirements of the ELAN
subnet, see the Planning and Engineering Guide (NN44200-200).

The second NIC, labeled NIC1-NickP can be connected to the Nortel
server subnet.

This optional NIC is required only for Meridian 1 or CS 1000 systems
that require a Nortel server subnet connection (in addition to the
ELAN subnet connection). The Nortel server subnet provides data
connectivity between desktop and Web messaging clients, Web-enabled
administrative PCs, and the CallPilot server.

Network requirements

Appropriate networking equipment must be available for both the Nortel
server subnet and ELAN subnet.

The Nortel server subnet and ELAN subnet must be properly configured
for correct CallPilot operation. To ensure correct configuration, Nortel
recommends that you consult a network specialist.

Nortel CallPilot

1005r Server Hardware Installation

NN44200-308

01.06

Standard

5.0

15 May 2008

Copyright © 2006-2008, Nortel Networks

.

Advertising