Bgd36cf(g) top or rear exit vertical termination – Napoleon Fireplaces BGD36CFPTR User Manual

Page 15

Advertising
background image

15

W415-0661 / C / 02.20.08

V

1

= 1.5 ft

V

2

= 5 ft

V

T

= V

1

+ V

2

= 1.5 + 5 = 6.5 ft

H

1

= 1 ft

H

2

= 1 ft

H

3

= 10.75 ft

H

R

= H

1

+ H

2

+ H

3

= 1 + 1 + 10.75 = 12.75 ft

H

O

= .03 (three 90° elbows + one 45° elbow - 90°)

= .03(90 + 90 + 90 + 45 - 90) = 6.75 ft

H

T

= H

R

+ H

O

= 12.75 + 6.75 = 19.5 ft

H

T

+ V

T

= 19.5 + 6.5 = 26 ft

Formula 1:

H

T

< 3V

T

3V

T

= 3 x 6.5 = 19.5 ft

19.5 < 19.5

Formula 2:

H

T

+ V

T

< 40 feet

26

<

40

Since both formulas are met, this vent confi guration is accept-
able.

H

2

H

3

V

1

V

2

90°

45°

90°

H

1

90°

BGD36CF(G) TOP OR REAR EXIT VERTICAL TERMINATION

FIGURE 33

Example 8: