W415-0661 / C / 02.20.08

After extended periods of non-operation such as following a
vacation or a warm weather season, the fi replace may emit a
slight odour for a few hours. This is caused by dust particles in
the heat exchanger burning off. In both cases, open a window
to suffi ciently ventilate the room.

Purge all gas lines with the glass door of the fi replace removed
or opened. Assure that a continuous gas fl ow is at the burner
before installing the door.

When lit for the fi rst time, the fi replace will emit a slight odour
for a few hours. This is a normal temporary condition caused
by the "burn-in" of internal paints and lubricants used in the
manufacturing process and will not occur again.

• Turn off all gas to the fi replace.

• Open

windows.

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any phone in your
building.

• Immediately call your gas supplier from a neighbour's phone.
Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fi re depart-
ment.

GAS KNOB

A. This fi replace is equipped with a pilot which must be lit by hand

while following these instructions exactly.

B. Before operating smell all around the fi replace area for gas and

next to the fl oor because some gas is heavier than air and will
settle on the fl oor.

C. Use only your hand to turn the gas control knob. Never use

tools. If the knob will not turn by hand, do not try to repair it. Call
a qualifi ed service technician. Force or attempted repair may
result in a fi re or explosion.

D. Do not use this fi replace if any part has been under water. Im-

mediately call a qualifi ed service technician to inspect the fi replace
and replace any part of the control system and any gas control
which has been under water.

WARNING: The gas valve has an interlock device which will not
allow the pilot burner to be lit until the thermocouple has cooled.
Allow approximately 60 seconds for the thermocouple to cool.

When lighting and re-lighting, the gas knob cannot be turned from
pilot to off unless the knob is depressed slightly.

1. Stop! Read the above safety information on this label.

2. Turn off all electric power to the fi replace.

3. Turn the gas knob clockwise to off.

4. Wait fi ve (5) minutes to clear out any gas. If you smell gas includ-
ing near the fl oor. Stop! Follow "B" in the above safety information
on this label. If you don't smell gas go the next step.

5. Turn gas knob counter-clockwise to pilot.

6. Depress slightly and hold gas knob while lighting the pilot with
the push button igniter. Keep knob depressed for one minute, then
release. If pilot does not continue to burn, repeat steps 3 through
5.

7. With pilot lit, depress and turn gas knob counter-clock-wise to
on.

8. If equipped with remote on-off switch/thermostat, main burner
may not come on when you turn valve to on. Remote switch must
be in the on position to ignite burner.

9. Turn on all electric power to the fi replace.

1. Turn off all electric power to the fi replace if service is to be
performed.

2. Push in gas control knob slightly and turn clockwise to off. Do
not force.

OPERATION BGD36CF & BGD42CF

FOR YOUR SAFETY READ BEFORE LIGHTING:

WHAT TO DO IF YOU SMELL GAS:

LIGHTING INSTRUCTIONS

TO TURN OFF GAS

TURN THE CONTROL VALVE TO THE OFF POSITION WHEN HEATER IS NOT IN USE.