Finished floor installation, Clean face surround minimum enclosure clearances – Napoleon Fireplaces BGD36CFPTR User Manual

Page 27

Advertising
background image

27

W415-0661 / C / 02.20.08

Installation requires a minimum of 6 1/2" non-combustible facing material at the top of the fi replace. Refer to either Figure 86a or Figure
86b
(depending on your installation) to ensure your fi replace has been installed with the proper requirements for this kit.

Whether installing to a fi nished fl oor or a hearth, a 3/8" clearance must be maintained at the bottom of the clean face surround kit. To obtain
this clearance a fi replace riser is required.

When installing to a fi nished fl oor the fi replace riser must create a minimum clearance of 3 3/8" from the fi nished fl oor to the bottom of the
fi replace.

WAVE

S36WN (BROWN)

S36WP (PEWTER)

CONCAVE

S36CCN (BROWN)

S36CCP (PEWTER)

CONVEX

S36CVN (BROWN)

S36CVP (PEWTER)

**

OPTIONAL CLEAN FACE SURROUND INSTALLATION BGD36CF(G) ONLY

FIGURE 85

FIGURE 83

FIGURE 84

FIGURE 81

FINISHED FLOOR INSTALLATION

NOTE:
** Installation requires a minimum 6 1/2" of non-combustible
facing above the top of the fi replace.

FINISHED

FLOOR

3

/

8

CLEARANCE

3

3

/

8

CLEANFACE SURROUND

STAND-OFF

6

1

/

2

MINIMUM

37

3

/

8

FINISHED

FLOOR

NON-COMBUSTIBLE

MATERIAL

COMBUSTIBLE

MATERIAL

FIREPLACE
RISER

3

/

8

CLEARANCE

3

3

/

8

FIREPLACE
RISER

STAND-OFF

CLEAN FACE

SURROUND

KIT

CLEAN FACE SURROUND KIT

STEEL

HEADER

STEEL

HEADER

FIGURE 82

FIGURE 86a

CLEAN FACE SURROUND MINIMUM ENCLOSURE CLEARANCES