SPECIAL VENT INSTALLATIONS

Use the GD201 periscope kit to locate the air termination above
grade. The periscope must be installed so that when fi nal grading
is completed, the bottom air slot is located a minimum of 12" above
grade. The maximum allowable vent length is 10'.

REAR EXIT INSTALLATION

TOP EXIT INSTALLATION

The maximum vent length for a corner installation is 20" of horizontal
run, in addition to the 45° offset. In this case zero rise is acceptable
when using rigid. See FIGURE 18. Flexible venting must maintain a
6" rise. See FIGURE 19.

PERISCOPE TERMINATION

CORNER TERMINATION

BGD36CF(G)

BGD42CF

PERISCOPE TERMINATION

Use the GD401 periscope kit to locate the air termination above
grade. The periscope must be installed so that when fi nal grading
is completed, the bottom air slot is located a minimum of 12" above
grade. The maximum allowable vent length is 10'.

FIGURE 15

FIGURE 16

FIGURE 18

FIGURE 19

FIGURE 17