Bgd42cf horizontal termination, 45° 90° h – Napoleon Fireplaces BGD36CFPTR User Manual

Page 16

Advertising
background image

16

W415-0661 / C / 02.20.08

BGD42CF HORIZONTAL TERMINATION

when (H

T

) < (V

T

)

Simple venting confi guration (only
one 45º and 90° elbow)

45°

90°

For vent confi gurations requiring more than one 45º and 90°
elbow, the following formulas apply:
Formula 1: HT < VT
Formula 2: HT + VT < 40 feet
Example 1:

45°

90°

H

1

H

2

V

1

REQUIRED
VERTICAL
RISE IN FEET
(V

T

)

CALCULATED HORIZONTAL VENT RUN

PLUS OFFSETS IN FEET (H

T

)

The shaded area within the lines represents acceptable values for
H

T

and V

T

.

V

1

= 8 ft

V

T

V

1

= 8 ft

H

1

= 2.5 ft

H

2

= 2 ft

H

R

= H

1

+ H

2

= 2.5 + 2 = 4.5 ft

H

O

= .03 (one 45° elbows + two 90° elbows - 135°)

= .03(225 - 135°) = 2.7 ft

H

T

= H

R

+ H

O

= 4.5 + 2.7 = 7.2 ft

H

T

+ V

T

= 7.2 + 8 = 15.2 ft

Formula 1:

H

T

< V

T

7.2 < 8

Formula 2:

H

T

+ V

T

< 40 feet

15.2

<

40

Since both formulas are met, this vent confi guration is acceptable.

FIGURE 34

FIGURE 35

when (H

T

) > (V

T

)

Simple venting con-
fi guration (only one
45º and 90° elbow)

See graph to deter-
mine the required
vertical rise V

T

for the

required horizontal
run H

T

.

REQUIRED VER-
TICAL RISE IN
INCHES V

T

HORIZONTAL VENT

RUN PLUS OFFSETS

IN FEET (H

T

)

The shaded area within the lines
represents acceptable values for H

T

and V

T

.

For vent confi gurations requiring more than one 45º and one 90°
elbow the following formulas apply:
Formula 1: HT < 4.2 VT
Formula 2: HT + VT < 24.75 feet

Example 2:

V

1

= 4 ft

V

2

= 1.5 ft

V

T

= V

1

+ V

2

= 4 + 1.5 = 5.5 ft

H

1

= 2 ft

H

2

= 1 ft

H

3

= 1 ft

H

4

= 1.5 ft

H

R

= H

1

+ H

2

+ H

3

+ H

4

= 2 + 1 + 1 + 1.5 = 5.5 ft

H

O

= .03 (one 45° elbow + four 90° elbows - 135°)

= .03(405 - 135) = 8.1 ft
H

T

= H

R

+ H

O

= 5.5 + 8.1 = 13.6 ft

H

T

+ V

T

= 13.6 + 5.5 = 19.1 ft

Formula 1:

H

T

< 4.2V

T

4.2V

T

= 4.2 x 5.5 = 23.1 ft

13.6 < 16.8

Formula 2:

H

T

+ V

T

< 24.75 feet

19.1

<

24.75

Since both formulas are met, this vent confi guration is accept-
able.

FIGURE 36

FIGURE 37

H

1

H

2

H

3

H

4

V

1

V

2

90°

45°

90°

90°

90°