BGD36CF(G) MINIMUM MANTEL AND ENCLOSURE CLEARANCES

Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed.

FIGURE 77

FIGURE 80

The fi replace requires a minimum enclosure height of 38 1/2“
(REAR VENT) 49" (TOP VENT). For temperature requirements,
the enclosure space around and above the fi replace must be left
unobstructed.

** See Venting Section

FIGURE 79

FIGURE 78

* If this unit is installed fl ush to the fi nishing material and optional
clean face surround is to be installed then a minimum of 6 1/2"
of cement board or non-combustible equivalent must be used on
the top only of the front face. See Figure 80.