NEC Express5800/120Rh-2 N8100-1126F User Manual

Page 116

Advertising
background image

4-20 Configuring Your Server

Running the Utility

To run the utility, perform the following procedures:

1.

Power on the server.

The following message appears while POST is in progress.

IMPORTANT:

The message appears for each additional SCSI

controller.

Adaptec SCSI BIOS Vxxx xxxxx
(c) 2000 Adaptec, Inc. All Rights Reserved



Press <Ctrl> <A> for SCSISelect(TM) Utility! 

2.

Press and hold Ctrl and A.

The SCSISelect utility starts and its Main menu appears.

3.

Select the channel and press Enter.

AIC-7902 A at Slot 23 02:03:00

AIC-7902 B at Slot 23 02:03:01

NOTE:

"AIC-7902A" is for backup file devices. "AIC-7902B" is for

internal SCSI hard disk drives.

The Options menu appears.

4.

Select option in the Options box and press Enter.

AIC-7902 at slot 23, 03:03:00

Would you like to configure the SCSI controller, or run the

SCSI Disk Utilities? Select the option and press <Enter>.

Options

SCSI Disk Utilities

Enable HostRAID Support

Configure/View SCSI Controller Settings

If you wish to configure the adapter or a device, select "Configure/View SCSI Controller
Settings".

If you wish to format a disk, verify disk media, or display a list of devices and their SCSI
IDs, select "SCSI Disk Utilities".

Advertising