Chapter 4 Signal Connections

National Instruments Corporation

4-21

DAQCard E Series User Manual

Digital I/O Signal Connections

The digital I/O signals are DIO<0..7> and DGND. The DIO<0..7>

signals make up the DIO port, and DGND is the ground reference
signal for this port. You can program all lines individually to be inputs
or outputs.

Warning:

Exceeding the maximum input voltage ratings, which are listed in
Tables 4-2 through 4-3, can damage the DAQCard and the computer.
National Instruments is

NOT

liable for any damages resulting from such

signal connections.

Figure 4-8 shows signal connections for three typical digital

I/O applications.

Figure 4-8.

Digital I/O Connections

LED

+5 V

TTL Signal

+5 V

DIO<4..7>

DIO<0..3>

DGND

Switch

I/O Connector

E Series Card