Querying the Network Interface Card firmware

Use this procedure to determine the current Network Interface Card (NIC)
firmware version.

Prerequisites

You must be assigned to the SSA role (ntsysadm)

Procedure Steps

Step

Action

1

Log on to the system as the SSA role (ntsysadm).

2

Run the following command:

sudo ethtool –i <ethernet_device>

The system displays the device properties, including the
currently installed firmware version.

firmware-version:

x.x.x

--End--

Variable definitions

Variable

Value

ethernet_device

eth0 or eth1

Querying the hard drive firmware

Use this procedure to determine the current hard drive firmware version.

Prerequisites

You must be assigned to the SSA role (ntsysadm)

Procedure Steps

Step

Action

1

Log on to the server as the SSA role (ntsysadm).

2

Run the following command:

arcconf GETCONFIG 1 pd

The system displays the physical device information for each
installed hard drive. The firmware version is included in the list
of information for each device.

Firmware :

xxxx

--End--