Firmware upgrades

101

Querying the ServeRaid firmware

Use this procedure to determine the current ServeRAID firmware version.

Prerequisites

You must be assigned to the SSA role (ntsysadm)

Procedure Steps

Step

Action

1

Log on to the server as the SSA role (ntsysadm).

2

Run the following command:

arcconf GETVERSION

The system displays information about the installed controllers.
The firmware version is included in the list of controller
information.

Firmware :

x.x-x (xxxxx)

--End--

Comparing the firmware versions to determine upgrade requirements

Firmware upgrades are necessary when the installed firmware versions
differ from the current firmware baselines. Use this procedure to compare
the currently installed firmware versions to the baseline versions.

Attention:

When determining if a firmware upgrade is required, ensure

that you are comparing firmware version information for the same
component.

Procedure Steps

Step

Action

1

Refer to the MR notes for a list mapping each firmware CD title
to its firmware version number.

2

Compare the firmware version listed in the text file for each
component with the currently installed firmware version for that
component.

If the versions match, no upgrade is necessary.

Application Server 5300

Nortel AS 5300 Installation

NN42040-300

01.04

4 November 2008