Using two dc power sources for power redundancy, Procedure – Nortel Networks HotWire 8600 User Manual

Page 30

Advertising
background image

Installing and Connecting the Hardware

2-14

8600-A2-GN20-20

October 1997

2. Dress the wires under the 8600 chassis to the left behind the support foot.

97-15446-01

-48V

RT

N

F
G

A

B

A

B

48VDC INPUT

AC

INPUT

AC

48VDC CLASS 2 OR

LIMITED PWR SOUR

RTN

–48V

A

A

B

B

T5A
250V

3. Power the HotWire 8600 DSLAM chassis.

4. Make sure the DC PWR A LED on the front panel is ON (green).

Using Two DC Power Sources for Power Redundancy

"

Procedure

To supply two dc power sources to the 8600 chassis for power redundancy:

Make sure that the dc power source wires are not powered (i.e., the
circuit breakers are open).

The ends power source wires (14 AWG – 18 AWG solid or stranded wire)
must be stripped of insulation to about 1/3-inch in length before plugging
the wires into the appropriate terminal on the – 48V input terminal block.

1. Insert the following wires in the appropriate terminal and securely fasten each

wire by tightening the screw directly above it. The insulation should be fully
within the terminal block and no bare wire should be exposed outside of the
block.

NOTE:

You should clearly label these power source wires as – 48V and RTN
respectively.