Leds, Overview, Hotwire 8600 dslam chassis – Nortel Networks HotWire 8600 User Manual

Page 50: Appendix a

Advertising
background image

A-1

8600-A2-GN20-20

October 1997

LEDs

A

Overview

This appendix describes the meaning of the LEDs on the HotWire 8600 DSLAM
chassis and MCC card.

HotWire 8600 DSLAM Chassis

The 8600 chassis allows addressable diagnostic connectivity between the MCC
and each of the DSL cards. It also converts and distributes – 48V power to the
cards in the chassis. In addition, it provides fans to cool the circuit cards.

The following table describes the meaning and states of the LEDs on the front
panel of the carrier.

LED

LED is . . .

Indicating . . .

DC PWR A

Green

Off

Normal operation for Power Source A.

Low, high, or no voltage for Power Source A.

DC PWR B

Green

Off

Normal operation for Power Source B.

Low, high, or no voltage for Power Source B.

FAN ALM

Yellow *

Off

Fan failure or a single fan in the Fan Module is working at
less than 50% of its normal output.

Normal operation or no power to mounting.

* A built-in feature shuts off power to the circuit cards if a chassis overheats because

of fan failure. If the temperature in the chassis reaches 70

°

C, power to

the cards in the chassis is turned off automatically. Power is turned on when the
temperature drops below 60

°

C.