Chapter 3

Configuration and Default Settings

© National Instruments Corporation

3-3

NI VXIpc-882 User Manual

Note

Do not adjust any jumpers or switches not listed in Table 3-1 or that are not

documented in this manual unless directed by National Instruments. Other configuration
jumpers are shown in the event National Instruments technical support needs to make
adjustments to your settings.

Default Software Settings

The following hardware configurations are available through
Measurement & Automation Explorer (MAX).

Table 3-1. NI VXIpc-882 Controller Hardware Default Settings

Jumper

Description

Setting

W2

SMB CLK10 DIR

1–2 In (Default)
2–3 Out

W3

External CLK10 Source Select

1–2 SMB (Default)
2–3 Trigger Card

W4

CLK10 Source Select

1–2 Internal Osc. (Default)
2–3 External Source

W5

MITE Configuration

1–2 Factory
2–3 User (Default)

W7

Trigger Card CLK10 Direction

1–2 Out
2–3 IN (Default)

W8

MITE Self Configuration

1–2 Disable
2–3 Enable (Default)

J2

Slot 0 Detect

1–2 Non-Slot 0
3–4 Auto Detect (Default)
5–6 Slot 0

Table 3-2. MAX Device Tab Default Settings

Editor Field

Default Setting

Device class

Message-based

Number of handlers

1