Chapter 3
Configuration and Default Settings
© National Instruments Corporation
3-3
Note
Do not adjust any jumpers or switches not listed in Table 3-1 or that are not
documented in this manual unless directed by National Instruments. Other configuration
jumpers are shown in the event National Instruments technical support needs to make
adjustments to your settings.
Default Software Settings
The following hardware configurations are available through
Measurement & Automation Explorer (MAX).
Table 3-1. NI VXIpc-882 Controller Hardware Default Settings
Jumper
Description
Setting
W2
SMB CLK10 DIR
1–2 In (Default)
2–3 Out
W3
External CLK10 Source Select
1–2 SMB (Default)
2–3 Trigger Card
W4
CLK10 Source Select
1–2 Internal Osc. (Default)
2–3 External Source
W5
MITE Configuration
1–2 Factory
2–3 User (Default)
W7
Trigger Card CLK10 Direction
1–2 Out
2–3 IN (Default)
W8
MITE Self Configuration
1–2 Disable
2–3 Enable (Default)
J2
Slot 0 Detect
1–2 Non-Slot 0
3–4 Auto Detect (Default)
5–6 Slot 0
Table 3-2. MAX Device Tab Default Settings
Editor Field
Default Setting
Device class
Message-based
Number of handlers
1