Operating Environment

Ambient temperature range ....................5

to 50 °C

(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)

Relative humidity range..........................10 to 90%, noncondensing

(Tested in accordance with
IEC-60068-2-56.)

Altitude ...................................................2,000 m (at 25

°C ambient

temperature)

Pollution Degree .....................................2

For indoor or enclosed area use only.

Module cooling requirements .................For 18

°C temperature rise,

2.6 liters/sec airflow,
0.03 mm H

2

O pressure across

module, per VXI-8, Cooling
Characterization Methodology
Specification

Caution

Clean the NI VXIpc-882 with a soft nonmetallic brush. Make sure that the device

is completely dry and free from contaminants before returning it to service.

Storage Environment

Ambient temperature range ....................–20

to 70 °C

(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)

Relative humidity range..........................5 to 95%, noncondensing

(Tested in accordance with
IEC-60068-2-56.)