Remote Maintenance by telnet

105

4

sntp

The printer clock can be synchronized
with a NTP server clock using Simple
Network Time Protocol (SNTP). Use
the "sntp" command to change SNTP
settings.

View settings

msh> sntp

NTP server address configuration

You can specify the IP address of
the NTP server.

msh> sntp server “IP_
address”

Interval configuration

msh> sntp interval “polling_
time”

• You can specify the interval at

which the printer synchronizes
with the operator-specified
NTP server. The default is 60
minutes.

• The interval can be entered be-

tween 16 and 16,384 minutes.

• If you set 0, the printer synchro-

nizes with the NTP server only
when you turn the printer on.
After that, the printer does not
synchronize with the NTP serv-
er.

Time-zone configuration

msh> sntp timezone “+/-
hour_time”

• You can specify the time differ-

ence between the printer clock
and NTP server clock. Time is in
24-hour format.

spoolsw

Use the “spoolsw” command to con-
figure Job Spool settings.
You can only specify diprint, lpr, ipp,
ftp and smb protocol.
• The “spoolsw” command for con-

figuring Job Spool settings is avail-
able only when the optional hard
disk is installed.

View settings

The Job Spool setting appears.

msh> spoolsw

Job Spool setting

msh> spoolsw spool {on | off}

Note

❒ Specify "on" to enable Job Spool,

or "off" to disable it.

Resetting Job spool setting

msh> spoolsw clear job {on
| off}

• When the printer power is cut

during job spooling, this deter-
mines whether to reprint the
spooled job.

Protocol configuration

msh> spoolsw diprint {on | off}
msh> spoolsw lpr {on | off}
msh> spoolsw ipp {on | off}
msh> spoolsw smb {on | off}
msh> spoolsw ftp {on | off}

• You can specify the settings for

diprint, lpr, ipp, and smb.