CB 1200 Pellet Stove

1

.

A 12 volt AC thermostat is required to operate this pellet

appliance. You may use the included wall mount thermo-

stat or purchase an optional programmable thermostat

or remote control. It is equipped with an adjustable

heat anticipator. The current rating is .05 amps. The

anticipator needs to be adjusted to the lowest setting

available.

2. When mounting a thermostat on a wall, be sure to follow

your thermostat installation instructions carefully.

NOTE: Thermostat must be mounted level for

accurate readings. The thermostat should be

mounted on an inside wall and not in direct line

with the appliance convection air.

NOTE: If the thermostat is located too close to the

appliance, you may need to set the temperature

setting slightly higher to maintain the desired

temperature in your home.

. There is a 4 screw terminal block located on the back

lower left corner of the stove directly above the power

cord inlet. The center 2 screws are for the thermostat

wires.

J. Thermostat Installation

Figure 21.1

Shock hazard.

• Do NOT remove grounding prong from plug.

• Plug directly into properly grounded  prong

receptacle.

• Route cord away from appliance.

• Do NOT route cord under or in front of appliance.

CAUTION

Power Outlet

Terminal Block.

Center 2 screws for

Thermostat Wires

I. Door Installation

To install door:
1. Carefully remove door from packaging.
2. Line up hinges with hinge pins on appliance body, and slide

door down until it sits securely on pins. Figure 21.1.

.

I

f door is plated, be sure to clean all plated surfaces and

glass with a glass cleaner to ensure all oils are removed

before your first burn.

4. Remove all labels from glass before burning appliance.

To adjust latches:
1. Close door securely.
2. Place rod in slot on the bracket on the door and close

latch.

. Latch must close tightly enough to ensure an airtight

seal between the door and the body of the appliance. To

increase tension on the latch, turn the rod clockwise a few

turns, then attempt to close the latch, until it is snug. Do not

overtighten; you should be able to close the latch with your

hand. Figure 21.2.

4. After adjusting the latch, place a Phillips head screw driver

in the end of the rod, and tighten the nut with a wrench.

This will maintain the correct tension on the rod and latch.