7014-082D

Page 5

CB 1200 Pellet Stove

11

Reference Materials

7. Heat Exchangers
The heat exchangers transfer hot air from the exhaust system

into convection air. Lift the stove top to access the heat

exchangers. There are 2 clean out rods located under the

heat exchangers.
8. Heat Output Switch
The heat output switch is located on the upper right side panel.

The function of the heat ouput switch is to regulate the burn

rates; low, medium, and high settings.
9. Igniter
The igniter is mounted on the base of the firepot. Combustion

air travels over the red hot igniter creating super heated air

that ignites the pellets.
10. Junction Box And Wiring Harness
The junction box is located on the right side of the appliance,

behind the interior shield. The junction box and wiring harness

are replaced as one component.
11. Power Supply
The power outlet is located on the back of the appliance,

lower right corner. Check the wall receptacle for 120 volt,

60 Hz (standard current). Make sure the outlet is grounded

and has the correct polarity. A good surge protector is

recommended.
12. Red Call Light
The red call light is on the front of the junction box, next to the

reset button. The function of the red call light is to indicate

that the thermostat is calling for heat.
13. Reset Button
The reset button is located on the right side of the apppliance

next to the red call light. The function of the button is to

momentarily open the thermostat circuit, which restarts the

system.
14. Thermocouple
The thermocouple is located on top of the firepot inside

the thermocouple cover (ceramic protection tube). The

thermocouple sends a millivolt signal to the control box

indicating the preset temperatures of the green and red lights

have been obtained.
15. Thermostat
The appliance is designed to run on a 12 volt AC thermostat.

The heat anticipator should be set on the lowest setting

available.

When describing the location of a component,

it is always AS YOU FACE THE FRONT OF

THE APPLIANCE.

2. Convection Blower
The convection blower is mounted at the bottom rear of the

appliance. There are 2 impellers, one on each side of the

motor. The convection blower pushes heated air through the

heat exchange system into the room.
3. Combustion (Exhaust) Blower
The combustion blower is mounted on the lower left side

on rear of appliance. The blower is designed to pull the

exhaust from the appliance and push it out through the

venting system.
4. Feed System
The feed system is located in the hopper under the feed

motor cover box on the left side of the appliance and can

be removed as an entire assembly. The assembly includes

the feed motor, mounting bracket, bearing and feed spring

(auger). The hollow feed spring (auger) pulls pellets up the

feed tube from the hopper area and drops them down the

feed chute into the firepot.
5. Firepot
The firepot is made of high quality ductile iron and has a

cleaning pull-out rod. The floor of the firepot opens for

cleaning when you pull out the rod. Be sure that the floor

returns to a completely closed position or your appliance will

not operate properly.
6. Fuse
The fuse is located on the front of the junction box on the

right side of the appliance. The fuse will blow should a short

occur and shut off power to the appliance.

NOTE:

Do

NOT open the control box. This will void the

warranty. If you need to plug in or remove the control

box you must first

unplug the appliance.

1. Control Box
a. The control box is located under a small cover in the

right rear corner of the inside of the hopper.

b. There is a light located inside of the control box. The

internal light will turn green when the appliance has

reached a temperature of 200

o

F (9°C) in the firepot

and will turn red when it reaches 600

o

F (15°C).

c. There is also an internal blue light located in the upper

left corner of the control box. When you plug in the

appliance the blue light will automatically start blinking

1 blink every 10 seconds for the first 60 seconds and

then will stop.