Vent information, Mt. vernon pellet stove (ae), A. venting termination minimum requirements – Quadra-Fire MTVERNON-AE-CWL User Manual

Page 10

Advertising
background image

Page 10

7034-106E

September 1, 2008

R

Mt. Vernon Pellet Stove (AE)

4

Vent Information

A. Venting Termination Minimum Requirements

J or K

X

V

M

I

H

A

V

G

B

V

V

A

B

V

F

V

C

B

B

E

L

V

D

V

Electrical

Service

V

N

V

N

V

N

N

V

Inside Corner

FIXED
CLOSED

OPEN

OPEN

FIXED
CLOSED

V

X

G

G

Termination Cap

Air Supply Inlet

Gas Meter

Restricted Area

O

P

Figure 10.1

OT

Termination must exhaust above air inlet elevation.

• It is recommended that at least 60 inches (1524mm) of

vertical pipe be installed when appliance is vented directly
through a wall. This will create a natural draft, which will
help prevent the possibility of smoke or odor venting into
the home during a power outage.

• It will also keep exhaust from causing a nuisance or hazard

by exposing people or shrubs to high temperatures.

• The safest and preferred venting method is to extend the

vent vertically through the roof or above the roof.

A

12 in.

Above Finish Grade (the grade surface
must be a non-combustible material

B

12 in.
48 in. no OAK

Open door or window: below or to the side

B

12 in.

Open door or window: above

C

6 in.

Permanently closed window: above, below
or to the side

D

18 in.
36 in. no OAK

Vertical clearance to a ventilated soffit
located above the terminal within a hori-
zontal distance of 2 ft from the center-line
of the terminal

E

12 in.

Clearance to unventilated soffit

F

12 in.

Clearance to outside corner

G

12 in.

Clearance to inside corner

H

36 in.

Above gas meter/regulator measured from
horizontal center-line of regulator

I

36 in. USA
72 in. Canada

Clearance to service regulator vent outlet

J

12 in.
48 in. no OAK

Clearance to non-mechanical air supply
inlet to the building or the combustions air
inlet to any other appliance

K

10 ft horizontal
3 ft vertical

Clearance to mechanical air supply

L

7 ft.

Above paved sidewalk, paved driveway
located on public property

M

12 in.

Under an open veranda, porch, deck or
balcony

N

See Note
below*

Electric service: above, below or to the
side (location must not obstruct or interfere
with access)

O

24 in.

Adjacent building, fences and protruding
parts of the structure

P

12 in.

Clearance above roof line for vertical
terminations

All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below.

24 in.

Above grass, top of plants, wood or any other com-
bustible

12 in.
36 in. no OAK

Clearance from any forced air intake of other appli-
ance

12 in.

Clearance horizontally from combustible wall

15 in.

Vented directly through a wall, minimum length of
horizontal pipe

6 in. horizontal
12 in. vertical

Minimum horizontal or vertical terminations must
protrude from wall

*NOTE: Consult local building, fire officials or authorities having jurisdic-
tion. Local codes or regulations may require different clearances.

OT

Do NOT Terminate Vent:

In any location that will allow flue gases or soot from enter-
ing or staining the building

• In any location which could create a nuisance or hazard

In any enclosed or semi-enclosed area such as a carport,
garage, attic, crawl space, under a sun deck or porch,
narrow walkway

• Closely fenced area, or any location that can build up

a concentration of fumes such as a stairwell, covered
breezeway, etc.