Mt. vernon pellet stove (ae), E. vertical - interior - typical installation – Quadra-Fire MTVERNON-AE-CWL User Manual

Page 15

Advertising
background image

R

September 1, 2008

7034-106E

Page 15

Mt. Vernon Pellet Stove (AE)

We recommend a minimum of 60 inches
(1524mm) vertical, however above the eave
is preferred.

All three installations are approved for mobile
home installations. Must use 3 or 4 inch (76
to 102mm) “L” or “PL” Listed pellet venting or
Listed double wall pipe and Quadra-Fire Out-
side Air Kit in mobile homes. Single wall pipe
is approved for residential installations only.

*NOTE: Clearance to combustibles are for
standard pellet pipe. If pellet pipe manufac-
turer allows reduced clearances to their pipe,
reduced clearances are allowed.

C. Vertical into Existing Class A Chimney

D. Through The Wall & Vertical - Exterior

Firestop

Flashing

Rain Cap

6 in.

(152mm)

Min.

Non-combustible Hearth Pad

3 in. (76mm) Min.

Clean-out Cover

12 in. (305mm) Minimum

Ceiling Support

3 to 6 in. (76-152mm)
Offset Adapter

6 in. (152mm) Class A
Chimney Connector
Adapter

3 to 3 in.
(76-76mm)
Top Vent Kit

Non-combustible Hearth Pad

Clean-out
Cover

Tee

Wall Thimble

Support
Bracket
every 60 in.
(1524mm)

12 in.
(305mm)
minimum

Rain
Cap

Flashing

2 in. (51mm) minimum

6 in. (152mm)

minimum

Figure 15.1

Figure 15.2

E. Vertical - Interior - Typical Installation

Firestop

Flashing

Rain Cap

6 in.

(152mm)

Min.

Non-combustible Hearth Pad

3 in. (76mm) Min.

Clean-out Cover

12 in.
(305mm)
Minimum

3 in. to 3 in.
(76-76mm)
Top Vent Kit

Figure 15.3

Advertising
This manual is related to the following products: