F. convection blower replacement – Quadra-Fire MTVERNON-AE-CWL User Manual

Page 36

Advertising
background image

Page 36

7034-106E

September 1, 2008

R

Mt. Vernon Pellet Stove (AE)

F. Convection Blower Replacement

Figure 36.1

Figure 36.3

epress a and

Snap t

Po er

S ppl

Remove
Left Side
Panel

Disconnect Wire Harness
from Bottom of Blower

Remove
Screws

Remove
Right Side
Panel

Figure 36.2

1. Follow the proper shut down procedures as outlined on

page 30, Section 10.A.

2. Remove the left and right side panels by removing the 4

screws using a Phillips head screw driver. Figure 36.1.

3. Depress the tab on the left side and snap out the power

supply. You do not need to disconnect any wires.
Figure 36.1.

4. Remove the 2 screws at the bottom of the back panel so

there will be room to remove the blower. Figure 36.1

5. Reach behind the blower and release the latch by push-

ing the top of the latch towards the blower. Figure 36.2.

6. Rock the top of the blower slightly and lift up. The

blower will pass around the control board and out the
left side of the appliance.

7. Disconnect the wire harness from the bottom of the

blower by depressing the tabs on the sides of the con-
nector and then pulling to remove. Figure 36.1.

8. Re-connect wire harness to the new blower.

9. Install replacement blower by placing the bottom flange

into the opening first then rotate blower up into posi-
tion.

10. When the blower is properly positioned the latch will engage

the notch to hold the blower in place. Figure 36.3.

11. Re-secure the back panel, snap the power supply back

in and re-secure the side panel(s).

ot h

Lat h

Lat h ngaged

Advertising