Mt. Vernon Pellet Stove (AE)

Fire Risk.

Inspection of Chimney:

Masonry chimney must be in good condition.

Meets minimum standard of NFPA 211

• Factory-built chimney must be 6 inch (152mm) UL103 HT.

WARNING

F. Masonry

G. Alternate Masonry

Non-combustible Hearth Pad

Airtight clean-out door

Sheathing

Flashing

1 in. (25mm) clearance

1 in. (25mm) clearance

with firestop

6 in. (152mm)
minimum

Fireclay Flue Liner
with airspace

Concrete Cap

2 in. (51mm) minimum to
combustible material

Figure 16.1

Figure 16.2

Non-combustible Hearth Pad

Airtight
Clean-out Door

Clean-out cover

Sheathing

1 in. (25mm) clearance

Flashing

Fireclay flue
liner with airspace

Concrete Cap

1 in. (25mm) clearance
with firestop

6 in. (152mm)
minimum

3 in. (76mm) minimum to
combustible material