Mt. Vernon Pellet Stove (AE)

9

Troubleshooting

With proper installation, operation, and maintenance your appliance will provide years of
trouble-free service. If you do experience a problem, this troubleshooting guide will assist
a qualified service person in the diagnosis of a problem and the corrective action to be
taken. This troubleshooting guide can only be used by a qualified service technician.

Error Message

Possible Cause

Corrective Action

Bad wall control or control board
3 wires have loose connections or installed
wrong

Replace wall control or control board
Check connections

LOW BATTERY

Battery supply on battery backup is drained

Recharge battery

BAD TC DROP TUBE

(TC = Thermocouple)

Drop tube thermocouple is broken or leads are
reversed

Check connections

Replace thermocouple

BAD TC FIREPOT

(TC = Thermocouple)

Firepot thermocouple is broken or leads are
reversed

Check connections

Replace thermocouple

SNAP DISC TRIPPED

Overheat sensor (snap disc) has tripped

Unplug the appliance and then manually
reset snap disc

VACUUM SW ERROR

(SW = Switch)

Vacuum switch is bad

Vacuum hose is plugged/disconnected

Check connections. Bypass vacuum
with jumper wire, if runs, switch is bad.
Replace switch

Check vacuum hose

COMB BLOWER JAMMED

Combustion blower is blocked/jammed

Remove blockage

Replace blower if necessary

Must uplug the appliance to clear the
error

AUGER JAMMED

Auger jammed, feed motor bad

Pull the feed system and inspect

Clear jam. Press Retry

MISSED IGNITION

Igniter bad or poor harness connection

Out of fuel or fuel is bridging in hopper

Faulty firepot thermocouple connection has
shorted.

Check connections, if OK replace igniter

Break up bridging pellets
Refill hopper

Replace the thermocouple and then
press Retry

MIN FIREPOT TEMP

Out of fuel

Refill hopper

Add handful of pellets to firepot

Press Retry

MAX DROP TUBE TEMP

Wrong fuel table setting

Flame height set too high

Confim setting matches burning fuel

Adjust flame height

CONV BLOWER JAMMED

Convection blower blocked/jammed

Remove blockage

Replace blower if necessary

Must uplug the appliance to clear the
error

CHECK ASHPAN

Auto-clean jammed

Auto-clean switch is bad

Linkage has become disconnected

If ashpan is empty, check for a jam. Use
a screw driver and firmly push in the
firepot floor holes and flex spring and
push toward home to release jam.

Replace switch

Reconnect linkage

Hopper lid open while you refill the hopper

Switch is out of adjustment (auger will not
function)

Fill hopper between cycle

Adjust or replace switch

SCREEN GOES BLANK

Static discharge or nearby lightening or

Electric fast transients at the input mains

Unplug the power to the appliance and
plug it back in