Getting started – Quadra-Fire MTVERNON-AE-CWL User Manual

Page 5

Advertising
background image

R

September 1, 2008

7034-106E

Page 5

Mt. Vernon Pellet Stove (AE)

2

Getting Started

A. Design, Installation & Location Considerations

Damaged parts could impair safe

operation. Do NOT install damaged, incomplete or substitute
components.

1. Appliance Location

OT

Check building codes prior to installation.

• Installation MUST comply with local, regional, state and

national codes and regulations.

• Consult insurance carrier, local building inspector, fire

officials or authorities having jurisdiction over restrictions,
installation inspection and permits.

It is a good idea to plan your installation on paper, using
exact measurements for clearances and floor protection,
before actually beginning the installation

Consideration must be given to:

• Safety, convenience, traffic flow

• Placement of the chimney and chimney connector.

• If you are not using an existing chimney, place the appli-

ance where there will be a clear passage for a factory-
built listed chimney through the ceiling and roof.

• Installing an optional outside air kit would affect the loca-

tion of the vent termination.

T O

If burning shelled field corn, you must use ap-

proved venting specifically designed for corn to prevent corro-
sion or degradation. Follow the instructions from the venting
manufacturer.

Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:

• Windows

• Air

Intakes

• Air

Conditioner

• Overhang, soffits, porch roofs, adjacent walls

• Landscaping,

vegetation

When locating vent and venting termination, vent above
roof line when possible.

Marginal Location

Below pea

Location NOT recommended

Not the highest point of the roof
Wind loading possi le

Multi-level Roofs

Windward

Leeward

Recommended
Outside Air Inta e
on windward side

NOT recommended
Outside Air Inta e
on leeward side

Recommended Location

A ove pea

Recommended

Insulated exterior chase

in cooler climates

Recommended Location

A ove pea
Inside heated space

Location NOT recommended

Too close to tree
Below ad acent structure
Lower roof line
Avoid outside wall

Marginal Location

Wind loading possi le

OT

Locating the appliance in a location of

considerable air movement can cause intermittent smoke
spillage from appliance. Do not locate appliance near:

Frequently open doors

Central heat outlets or returns

Figure 5.1

Advertising