Quadra-Fire QF130 User Manual

Page 11

Advertising
background image

11

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

Initial Break-in Procedure
• The appliance should be run three to four hours

continuously on high.

• Turn the appliance off and allow it to completely cool.
• Remove fi xed glass assembly. See Section 12.H.
• Clean fi xed glass assembly. See Section 3.
• Replace the fi xed glass assembly and run continuously

on high an additional 9 hours.

This cures the materials used to manufacture the fi re-

place.
NOTICE! Open windows for air circulation during ap-

pliance break-in.

• Some people may be sensitive to smoke and odors.

• Smoke detectors may activate.

K. After Appliance is Lit

L. Frequently Asked Questions

ISSUE

SOLUTIONS

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance warms, this

condensation will disappear.

Blue fl ames

This is a result of normal operation and the fl ames will begin to yellow as the appliance is al-

lowed to burn for 20 to 40 minutes.

Odor from appliance

When fi rst operated, this appliance may release an odor for the fi rst several hours. This is caused

by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor may

also be released from fi nishing materials and adhesives used around the appliance.

Film on the glass

This is a normal result of the curing process of the paint and logs. Glass should be cleaned

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing

process. A non-abrasive cleaner such as gas fi replace glass cleaner may be necessary. See

your dealer.

Metallic noise

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to

the sound produced by a furnace or heating duct. This noise does not affect the operation or

longevity of the appliance.

Is it normal to see the pilot fl ame burn

continually?

In an intermittent pilot ignition system (IPI), the pilot fl ame should turn off when appliance is

turned off. Some optional control systems available with IPI models may allow pilot fl ame to

remain lit.