Installing vent pipe and appliance, B. venting components, C. connecting vent pipe – Quadra-Fire QF130 User Manual

Page 21: A. vent limits

Advertising
background image

21

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

B. Venting Components

CAUTION! Risk of Cuts/Abrasions/Flying Debris.

Wear protective gloves and safety glasses during instal-

lation. Sheet metal edges are sharp.
The vertical vent termination system installed on this model

includes:
• Flexible vent pipe for exhaust air (included with vent kit).
• One length of 3-inch fl exible vent pipe for combustion

air (included with vent kit).

• One pipe-to-cap adaptor (included with vent kit).
• One vertical termination cap (included with vent kit).

8

Installing Vent Pipe and Appliance

Figure 8.1

C. Connecting Vent Pipe

Reference instructions in the termination kit.
• Install the 3-inch fl exible vent pipe(s) down through the

chimney.

• Secure the exhaust fl exible vent pipe to the exhaust

starting collar on top of the appliance with three screws

and seal with stove cement rated for continuous

exposure to 1200ºF or higher. See Figure 8.1.

• Use 3 screws to attach the section of inlet air vent to

the inlet collar on the collar slide plate and seal with

stove cement rated for continuous exposure to 1200ºF

or higher. See Figure 8.1. NOTE: The collar slide plate

may be removed from appliance to aid installation.

WARNING! Risk of Fire/Explosion/Asphyxiation! Do

NOT connect this gas appliance to a chimney fl ue serving

a separate solid fuel or gas burning appliance.
• May impair safe operation of this appliance or other

appliances connected to the fl ue.

• Vent this appliance directly outside.
• Use separate vent system for this appliance.

Horizontal venting is NOT allowed.
Vertical terminations are measured to top of chimney.
This appliance is listed for use with LINK-DV systems

and components only. It is permissible to extend venting

above existing chimney (within specifi ed maximum verti-

cal limits) using SL-D series or Dura Vent GS series 4 in.

x 6-5/8 in. gas direct-vent pipe. Connection is made us-

ing DV-46DVA-GK. The vent must be terminated with the

cap supplied with the LINK-series vent kit.

A. Vent Limits

The abbreviations listed in this vent table key are used in

the vent diagrams.

Description

Minimum Vertical Run Length 10 ft.

Maximum Vertical Run Length 50 ft.

CAUTION! ALL vent specifi cations MUST be followed.

This product is tested and listed to these specifi cations.

Appliance performance will suffer if specifi cations are not

followed.

EXHAUST

AIR

VENT PIPE

TERMINATION

CAP

EXHAUST STARTING COLLAR

STARTING COLLAR BRACKET

EXHAUST STARTING COLLAR

INLET AIR STARTING COLLAR

STARTING COLLAR BRACKET

INLET AIR STARTING COLLAR

LOCKING TAB

INLET AIR

VENT PIPE

ADAPTER

V = 10 FT. MINIMUM

50 FT. MAXIMUM

NOTE: TO ACHIEVE OPTIMUM PERFOR-

MANCE OF INSERT, MINIMIZE OR AVOID

BENDS IN EXHAUST VENT PIPE.

EXHAUST

COLLAR

INLET

COLLAR

HANDLE