Electrical information, A. wiring requirements, B. intellifire plus™ ignition system wiring – Quadra-Fire QF130 User Manual

Page 25

Advertising
background image

25

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

A. Wiring Requirements

NOTICE: This appliance must be electrically wired

and grounded in accordance with local codes or, in the

absence of local codes, with

National Electric Code

ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.
• This appliance comes standard with a 120 VAC cord

assembly which has a female plug in to accommodate

all control options and accessories. See Figure 10.2.

This is required for proper operation of the appliance

(IntelliFire Plus Ignition). An outlet box may be installed

in a bottom back corner of the existing solid fuel masonry

or factory built fi replace to plug in the cord assembly,

or the supplied power cord may be routed out onto the

hearth to a nearby outlet.

• A 120 VAC circuit for this product must be protected with

ground-fault circuit-interrupter protection, in compliance

with the applicable electrical codes, when it is installed in

locations such as in bathrooms or near sinks.

• Low voltage and 120 VAC voltage cannot be shared

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire

120V to the valve or to the appliance wall switch. Incor-

rect wiring will damage controls.
• An Intellifi re Plus

Ignition System is standard with this

appliance.

10

Electrical Information

B. IntelliFire Plus™ Ignition System Wiring

• Wire an outlet box (120VAC) in the bottom back corner of

the existing solid fuel masonry or factory built fi replace to

plug in the cord assembly. The supplied cord assembly

may also be routed out onto the hearth to a nearby outlet.

WARNING! Risk of Shock or Explosion! DO NOT wire

IPI controlled appliance junction box to a switched circuit.

Incorrect wiring will override IPI safety lockout.
• Refer to Figure 10.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus™

control valve which operates on a 6 volt/1.5 AMP

system.

• Plug the 6 volt transformer plug into the cord assembly

to supply power to the unit OR install 4 AA cell batteries

(not included) into the battery pack before use.

ON/OFF Switch
• An ON/OFF switch is included with the appliance

surround and should be attached to surround/facing.

(See Installation instructions for remote control/fronts).

• If desired an additional wall switch or thermostat may

be added to system as shown in Figure 10.1.

Figure 10.1 IPI Wiring Diagram

BLK

RED

BATTERY PACK

6V DC

GROUND

BROWN

GREEN

(MAIN)

ROCKER

SWITCH

ORANGE

(PILOT)

WALL SWITCH

OR REMOTE

INSTALL

TO CORD ASSEMBLY

120VAC

INTERMITTENT

PILOT IGNITOR

RC100 RC200 RC300

(OPTIONAL WALL CONTROLS)

TO CORD

ASSEMBLY

(110V)

WHT

ORG

MODULE

FLAME

MODULATION

AUX1 AUX2

AUX300 MODULE

FAN

BLK

RED

AUX2 NOT USED FOR INSERT MODELS.

PROTECTIVE COVER INCLUDED